How to Choose the Right Dry type transformer Enclosure for Your Factory or Supplier

When selecting a Dry type transformer enclosure for your factory or supplier, it is important to consider the environment in which the transformer will be installed. The enclosure must be able to withstand the environmental conditions of the area, such as temperature, humidity, and dust. Additionally, the enclosure must be able to protect the transformer from any potential hazards, such as fire, water, and corrosion. The first step in choosing the right Dry type transformer enclosure is to determine the size and type of transformer that will be installed. This will help you determine the size and type of enclosure that is needed. Additionally, you should consider the type of cooling system that will be used, as this will affect the size and type of enclosure that is needed. Once you have determined the size and type of transformer and cooling system, you should consider the type of enclosure that is best suited for the environment. For example, if the transformer will be installed in a humid environment, then a stainless steel enclosure may be the best option. On the other hand, if the transformer will be installed in a dry environment, then a galvanized steel enclosure may be the best option.
TypeRated capacity (KVA)Voltage combination(KV)No-load losses(W)Load losses(W)No-load current (%)Short-circuit impedance (%)
SCH15-30306,6.3,6.6,10,11/0.4707101.64.0
SCH15-50506,6.3,6.6,10,11/0.49010001.44.0
SCH15-80806,6.3,6.6,10,11/0.412013801.34.0
SCH15-1001006,6.3,6.6,10,11/0.413015701.24.0
SCH15-1251256,6.3,6.6,10,11/0.415018501.14.0
SC(B)H15-1601606,6.3,6.6,10,11/0.417021301.14.0
SC(B)H15-2002006,6.3,6.6,10,11/0.420025301.04.0
SC(B)H15-2502506,6.3,6.6,10,11/0.423027601.04.0
SC(B)H15-3153156,6.3,6.6,10,11/0.428034700.94.0
SC(B)H15-4004006,6.3,6.6,10,11/0.431039900.84.0
SC(B)H15-5005006,6.3,6.6,10,11/0.436048800.84.0
SC(B)H15-6306306,6.3,6.6,10,11/0.442058800.74.0
SC(B)H15-6306306,6.3,6.6,10,11/0.441059600.76.0
SC(B)H15-8008006,6.3,6.6,10,11/0.448069600.76.0
SC(B)H15-100010006,6.3,6.6,10,11/0.455081300.66.0
SC(B)H15-125012506,6.3,6.6,10,11/0.465096900.66.0
SC(B)H15-160016006,6.3,6.6,10,11/0.4780117300.66.0
SC(B)H15-200020006,6.3,6.6,10,11/0.41000144500.56.0
SC(B)H15-250025006,6.3,6.6,10,11/0.41200171700.56.0
Finally, you should consider the safety features of the enclosure. The enclosure should be able to protect the transformer from any potential hazards, such as fire, water, and corrosion. Additionally, the enclosure should be able to protect the transformer from any potential electrical hazards, such as short circuits and overloads. alt-496 By taking the time to consider the size and type of transformer, the type of cooling system, and the safety features of the enclosure, you can ensure that you select the right Dry type transformer enclosure for your factory or supplier.