How to Choose the Right 3 phase Power transformer for Large Production: A Guide for Manufacturers

Manufacturers of large production facilities require a reliable and efficient 3 phase Power transformer to ensure the smooth operation of their production line. Choosing the right 3 phase Power transformer for a large production facility is a critical decision that requires careful consideration of several factors. This guide outlines the key considerations for manufacturers when selecting a 3 phase Power transformer for their large production facility. 1. Power Rating: The power rating of a 3 phase Power transformer is the maximum amount of power it can handle. It is important to select a transformer with a power rating that is sufficient for the needs of the production facility. The power rating should be determined based on the total power requirements of the facility, including the power requirements of all the machines and equipment. 2. Voltage Rating: The voltage rating of a 3 phase Power transformer is the maximum voltage it can handle. It is important to select a transformer with a voltage rating that is sufficient for the needs of the production facility. The voltage rating should be determined based on the total voltage requirements of the facility, including the voltage requirements of all the machines and equipment.
3. Efficiency: The efficiency of a 3 phase Power transformer is an important factor to consider when selecting a transformer for a large production facility. The efficiency of a transformer is determined by its ability to convert electrical energy into mechanical energy with minimal losses. It is important to select a transformer with a high efficiency rating to ensure that the production facility is operating at its maximum efficiency. 4. Size: The size of a 3 phase Power transformer is an important factor to consider when selecting a transformer for a large production facility. The size of the transformer should be determined based on the total power and voltage requirements of the facility, as well as the physical space available for the transformer. It is important to select a transformer that is the right size for the facility to ensure that it is able to handle the power and voltage requirements of the facility. 5. Cost: The cost of a 3 phase Power transformer is an important factor to consider when selecting a transformer for a large production facility. It is important to select a transformer that is cost-effective and provides the best value for money. The cost of the transformer should be determined based on the total power and voltage requirements of the facility, as well as the efficiency rating of the transformer. By considering these key factors, manufacturers can ensure that they select the right 3 phase Power transformer for their large production facility. It is important to select a transformer that is reliable, efficient, and cost-effective to ensure that the production facility is operating at its maximum efficiency.
TypeRated capacity (KVA)No-load losses(W)Voltage combination (KV)Load losses(W)No-load current (%)Short-circuit impedance (%)
S11-M-30301006,6.3,10,10.5,11/0.46002.34.0
S11-M-50501306,6.3,10,10.5,11/0.48702.04.0
S11-M-63631506,6.3,10,10.5,11/0.410401.94.0
S11-M-80801806,6.3,10,10.5,11/0.412501.94.0
S11-M-1001002006,6.3,10,10.5,11/0.415001.84.0
S11-M-1251252406,6.3,10,10.5,11/0.418001.74.0
S11-M-1601602806,6.3,10,10.5,11/0.422001.64.0
S11-M-2002003406,6.3,10,10.5,11/0.426001.54.0
S11-M-2502504006,6.3,10,10.5,11/0.430501.44.0
S11-M-3153154806,6.3,10,10.5,11/0.436501.44.0
S11-M-4004005706,6.3,10,10.5,11/0.443001.34.0
S11-M-5005006806,6.3,10,10.5,11/0.451001.24.0
S11-M-6306308106,6.3,10,10.5,11/0.462001.14.5
S11-M-8008009806,6.3,10,10.5,11/0.475001.04.5
S11-M-1000100011506,6.3,10,10.5,11/0.4103001.04.5
S11-M-1250125013606,6.3,10,10.5,11/0.4128000.94.5
S11-M-1600160016406,6.3,10,10.5,11/0.4145000.84.5
S11-M-2000200022806,6.3,10,10.5,11/0.4178200.65.0
S11-M-2500250027006,6.3,10,10.5,11/0.4207000.65.0
S11-M-30-309020,22/0.46602.15.5
S11-M-50-5013020,22/0.496025.5
S11-M-63-6315020,22/0.411451.95.5
S11-M-80-8018020,22/0.413701.85.5
S11-M-100-10020020,22/0.416501.65.5
S11-M-125-12524020,22/0.419801.55.5
S11-M-160-16029020,22/0.424201.45.5
S11-M-200-20033020,22/0.428601.35.5
S11-M-250-25040020,22/0.433501.25.5
S11-M-315-31548020,22/0.440101.15.5
S11-M-400-40057020,22/0.4473015.5
S11-M-50050068020,22/0.4566015.5
S11-M-63063081020,22/0.468200.96
S11-M-80080098020,22/0.482501.86
S11-M-10001000115020,22/0.4113300.76
S11-M-12501250135020,22/0.4132000.76
S11-M-16001600163020,22/0.4159500.66

Similar Posts