alt-841 One way Oil filled transformers are becoming more eco-friendly is through the use of biodegradable oils. These oils are made from vegetable-based materials and are designed to break down naturally over time. This reduces the risk of environmental contamination and eliminates the need for hazardous waste disposal. Additionally, these oils are non-toxic and non-flammable, making them safer to use and handle. Another way Oil filled transformers are becoming more eco-friendly is through the use of advanced insulation materials. These materials are designed to reduce the amount of energy lost during operation, resulting in lower energy consumption and fewer emissions. Additionally, these materials are designed to be more durable and resistant to wear and tear, reducing the need for frequent maintenance and repairs. Finally, Oil filled transformers are becoming more maintenance free through the use of self-monitoring systems. These systems are designed to detect any potential problems and alert operators to take corrective action. This reduces the need for manual inspections and repairs, resulting in fewer disruptions to the electrical grid. Overall, Oil filled transformers are becoming more eco-friendly and maintenance free through the use of biodegradable oils, advanced insulation materials, and self-monitoring systems. These improvements are helping to reduce energy consumption and emissions, while also making the electrical grid more reliable and efficient.

Exploring the Benefits of Investing in an Oil filled transformer Manufacturing Company

TypeRated capacity (KVA)Voltage combination(KV)No-load losses(W)Load losses(W)No-load current (%)Short-circuit impedance (%)
SZ11-2000200033,35/6.3,6.6,10.5,112300192400.806.5
SZ11-2500250033,35/6.3,6.6,10.5,112720206400.806.5
SZ11-3150315033,35/6.3,6.6,10.5,113230247100.727.0
SZ11-4000400033,35/6.3,6.6,10.5,113870291600.727.0
SZ11-5000500033,35/6.3,6.6,10.5,114640342000.687.0
SZ11-6300630033,35/6.3,6.6,10.5,115630368000.687.5
SZ11-8000800033,35/6.3,6.6,10.5,117870406000.607.5
SZ11-100001000033,35/6.3,6.6,10.5,119280481000.607.5
SZ11-125001250033,35/6.3,6.6,10.5,1110940569000.568.0
SZ11-160001600033,35/6.3,6.6,10.5,1113170703000.548.0
SZ11-200002000033,35/6.3,6.6,10.5,1115570828000.548.0