Exploring the Benefits of Oil Insulated Transformers with On-Load Tap Changers
Oil insulated transformers with on-load tap changers are becoming increasingly popular in the power industry. These transformers offer a number of benefits that make them an attractive option for many applications.
One of the main advantages of oil insulated transformers with on-load tap changers is their ability to adjust the voltage output without having to shut down the transformer. This is especially useful in applications where the voltage needs to be adjusted frequently, such as in power grids. With an on-load tap changer, the voltage can be adjusted while the transformer is still running, which saves time and money.
Another benefit of oil insulated transformers with on-load tap changers is their increased efficiency. These transformers are designed to reduce losses and improve efficiency, which can lead to lower energy costs. This is especially beneficial in applications where energy costs are a major factor.
Finally, oil insulated transformers with on-load tap changers are also more reliable than other types of transformers. These transformers are designed to be more durable and reliable, which can help reduce downtime and maintenance costs.
Type
Rated capacity (KVA)
No-load losses(W)
Voltage combination (KV)
Load losses(W)
No-load current (%)
Short-circuit impedance (%)
S11-M-30
30
100
6,6.3,10,10.5,11/0.4
600
2.3
4.0
S11-M-50
50
130
6,6.3,10,10.5,11/0.4
870
2.0
4.0
S11-M-63
63
150
6,6.3,10,10.5,11/0.4
1040
1.9
4.0
S11-M-80
80
180
6,6.3,10,10.5,11/0.4
1250
1.9
4.0
S11-M-100
100
200
6,6.3,10,10.5,11/0.4
1500
1.8
4.0
S11-M-125
125
240
6,6.3,10,10.5,11/0.4
1800
1.7
4.0
S11-M-160
160
280
6,6.3,10,10.5,11/0.4
2200
1.6
4.0
S11-M-200
200
340
6,6.3,10,10.5,11/0.4
2600
1.5
4.0
S11-M-250
250
400
6,6.3,10,10.5,11/0.4
3050
1.4
4.0
S11-M-315
315
480
6,6.3,10,10.5,11/0.4
3650
1.4
4.0
S11-M-400
400
570
6,6.3,10,10.5,11/0.4
4300
1.3
4.0
S11-M-500
500
680
6,6.3,10,10.5,11/0.4
5100
1.2
4.0
S11-M-630
630
810
6,6.3,10,10.5,11/0.4
6200
1.1
4.5
S11-M-800
800
980
6,6.3,10,10.5,11/0.4
7500
1.0
4.5
S11-M-1000
1000
1150
6,6.3,10,10.5,11/0.4
10300
1.0
4.5
S11-M-1250
1250
1360
6,6.3,10,10.5,11/0.4
12800
0.9
4.5
S11-M-1600
1600
1640
6,6.3,10,10.5,11/0.4
14500
0.8
4.5
S11-M-2000
2000
2280
6,6.3,10,10.5,11/0.4
17820
0.6
5.0
S11-M-2500
2500
2700
6,6.3,10,10.5,11/0.4
20700
0.6
5.0
S11-M-30-
30
90
20,22/0.4
660
2.1
5.5
S11-M-50-
50
130
20,22/0.4
960
2
5.5
S11-M-63-
63
150
20,22/0.4
1145
1.9
5.5
S11-M-80-
80
180
20,22/0.4
1370
1.8
5.5
S11-M-100-
100
200
20,22/0.4
1650
1.6
5.5
S11-M-125-
125
240
20,22/0.4
1980
1.5
5.5
S11-M-160-
160
290
20,22/0.4
2420
1.4
5.5
S11-M-200-
200
330
20,22/0.4
2860
1.3
5.5
S11-M-250-
250
400
20,22/0.4
3350
1.2
5.5
S11-M-315-
315
480
20,22/0.4
4010
1.1
5.5
S11-M-400-
400
570
20,22/0.4
4730
1
5.5
S11-M-500
500
680
20,22/0.4
5660
1
5.5
S11-M-630
630
810
20,22/0.4
6820
0.9
6
S11-M-800
800
980
20,22/0.4
8250
1.8
6
S11-M-1000
1000
1150
20,22/0.4
11330
0.7
6
S11-M-1250
1250
1350
20,22/0.4
13200
0.7
6
S11-M-1600
1600
1630
20,22/0.4
15950
0.6
6
Overall, oil insulated transformers with on-load tap changers offer a number of benefits that make them an attractive option for many applications. They are more efficient, reliable, and can be adjusted without having to shut down the transformer. If you’re looking for a reliable and efficient transformer, oil insulated transformers with on-load tap changers may be the perfect solution.