Exploring the Benefits of Vacuum Cast Coil (VCC) Dry type transformers from China
Vacuum Cast Coil (VCC) Dry type transformers from China offer a number of advantages over traditional oil-filled transformers. VCC transformers are designed to be more efficient, reliable, and cost-effective than their oil-filled counterparts.
The most significant benefit of VCC transformers is their increased efficiency. VCC transformers are designed to reduce energy losses due to their unique construction. The coils are vacuum cast in a special resin, which eliminates air gaps and reduces the amount of heat generated during operation. This reduces energy losses and increases the efficiency of the transformer.
Type
Rated capacity (KVA)
Voltage combination(KV)
No-load losses(W)
Load losses(W)
No-load current (%)
Short-circuit impedance (%)
SC13-30
30
6,6.3,6.6,10,11/0.4
150
710
2.3
4.0
SC13-50
50
6,6.3,6.6,10,11/0.4
215
1000
2.2
4.0
SC13-80
80
6,6.3,6.6,10,11/0.4
295
1380
1.7
4.0
SC13-100
100
6,6.3,6.6,10,11/0.4
320
1570
1.7
4.0
SC13-125
125
6,6.3,6.6,10,11/0.4
375
1850
1.5
4.0
SCB13-160
160
6,6.3,6.6,10,11/0.4
430
2130
1.5
4.0
SCB13-200
200
6,6.3,6.6,10,11/0.4
495
2530
1.3
4.0
SCB13-250
250
6,6.3,6.6,10,11/0.4
575
2760
1.3
4.0
SCB13-315
315
6,6.3,6.6,10,11/0.4
705
3470
1.1
4.0
SCB13-400
400
6,6.3,6.6,10,11/0.4
785
3990
1.1
4.0
SCB13-500
500
6,6.3,6.6,10,11/0.4
930
4880
1.1
4.0
SCB13-630
630
6,6.3,6.6,10,11/0.4
1070
5880
0.9
4.0
SCB13-630
630
6,6.3,6.6,10,11/0.4
1040
5960
0.9
6.0
SCB13-800
800
6,6.3,6.6,10,11/0.4
1210
6960
0.9
6.0
SCB13-1000
1000
6,6.3,6.6,10,11/0.4
1410
8130
0.9
6.0
SCB13-1250
1250
6,6.3,6.6,10,11/0.4
1670
9690
0.9
6.0
SCB13-1600
1600
6,6.3,6.6,10,11/0.4
1960
11700
0.9
6.0
SCB13-2000
2000
6,6.3,6.6,10,11/0.4
2440
14400
0.7
6.0
SCB13-2500
2500
6,6.3,6.6,10,11/0.4
2880
17100
0.7
6.0
VCC transformers are also more reliable than traditional oil-filled transformers. The vacuum casting process eliminates the need for insulation materials, which can degrade over time and cause short circuits. This increases the reliability of the transformer and reduces the risk of failure.
Finally, VCC transformers are more cost-effective than traditional oil-filled transformers. The vacuum casting process eliminates the need for insulation materials, which can be expensive. Additionally, the increased efficiency of VCC transformers reduces energy costs, which can further reduce the overall cost of ownership.
In conclusion, VCC Dry type transformers from China offer a number of advantages over traditional oil-filled transformers. They are more efficient, reliable, and cost-effective, making them an attractive option for many applications.
When selecting a VCC Dry type transformer for an application, there are several factors to consider. First, the transformer must be rated for the voltage and current requirements of the application. The transformer should also be designed to meet the environmental conditions of the application, such as temperature, humidity, and altitude. Additionally, the transformer should be designed to meet any safety requirements, such as UL or CSA certification.
The transformer should also be sized to meet the power requirements of the application. This includes the power factor, efficiency, and impedance of the transformer. The transformer should also be designed to meet any harmonic requirements of the application.
Finally, the transformer should be designed to meet any special requirements of the application, such as noise reduction, surge protection, or harmonic mitigation.
By considering all of these factors, it is possible to select the right VCC Dry type transformer for an application.
Understanding the Different Types of VCC Dry type transformers and Their Applications
VCC Dry type transformers are a type of Electrical transformer that is designed to operate without the use of oil or other cooling fluids. They are commonly used in industrial, commercial, and residential applications.
The two main types of VCC Dry type transformers are core form and shell form. Core form transformers are constructed with a core made of stacked laminations of steel. The windings are then wound around the core. This type of transformer is typically used in applications where space is limited.
Shell form transformers are constructed with a core made of a single piece of steel. The windings are then wound around the core. This type of transformer is typically used in applications where space is not an issue.
VCC Dry type transformers are used in a variety of applications, including power distribution, voltage regulation, and motor control. They are also used in applications where the transformer must be located in a hazardous or corrosive environment.
VCC Dry type transformers are designed to be reliable and efficient. They are also designed to be cost-effective, as they do not require the use of oil or other cooling fluids.
VCC Dry type transformers are available in a variety of sizes and ratings. The size and rating of the transformer will depend on the application and the power requirements. It is important to select the correct size and rating for the application to ensure optimal performance.
Manteision Defnyddio Trawsnewidyddion Compact mewn Cymwysiadau Diwydiannol Mae trawsnewidyddion compact wedi dod yn elfen hanfodol mewn cymwysiadau diwydiannol amrywiol oherwydd eu…
Manteision Defnyddio Trawsnewidyddion Math Hylif mewn Cymwysiadau Diwydiannol Mae trawsnewidyddion math hylif yn elfen hanfodol mewn llawer o gymwysiadau diwydiannol, gan…
Sut mae Trawsnewidyddion Math Sych wedi’u Hinswleiddio â Resin yn Gwella Effeithlonrwydd Generaduron Mae effeithlonrwydd generadur yn ffactor pwysig yn llwyddiant…