Understanding the Benefits of an Enclosed Dry type transformer from a China Manufacturer: How to Ensure Over Temperature Alarm Protection
Customer: Hi, I’m looking for an enclosed Dry type transformer from a China manufacturer. I understand the benefits of this type of transformer, but I’m wondering how I can ensure over temperature alarm protection?
Manufacturer: Hi, thanks for your interest in our enclosed Dry type transformers. We understand the importance of over temperature alarm protection and have taken steps to ensure that our transformers are equipped with the necessary features.
First, our transformers are designed with a built-in temperature sensor that will detect any rise in temperature and trigger an alarm. This alarm will alert you to any potential issues before they become a problem.
Second, our transformers are also equipped with a thermal protection system. This system will automatically shut down the transformer if the temperature rises above a certain level. This will help to prevent any damage to the transformer and ensure that it is operating safely.
Type
Rated capacity (KVA)
Voltage combination(KV)
No-load losses(W)
Load losses(W)
No-load current (%)
Short-circuit impedance (%)
SC10-800
800
33,35,38/6,6.3,6.6,10,11
2200
9400
1.1
6.0
SC10-1000
1000
Voltage combination(KV)
2610
10800
1.1
6.0
SC10-1250
1250
6,6.3,6.6,10,11/0.4
3060
11900
1.0
6.0
SC10-1500
1500
Voltage combination(KV)
3600
15400
1.0
6.0
SC10-2000
2000
6,6.3,6.6,10,11/0.4
4130
18200
0.9
7.0
SC10-2500
2500
Voltage combination(KV)
4750
21800
0.9
7.0
SC10-3150
3150
6,6.3,6.6,10,11/0.4
5880
24500
0.8
8.0
SC10-4000
4000
Voltage combination(KV)
6860
29400
0.8
8.0
SC10-5000
5000
6,6.3,6.6,10,11/0.4
8180
34960
0.7
8.0
SC10-6300
6300
Voltage combination(KV)
9680
40800
0.7
8.0
SC10-8000
8000
6,6.3,6.6,10,11/0.4
11000
46060
0.6
9.0
SC10-10000
10000
Voltage combination(KV)
12660
56500
0.6
9.0
SC10-12500
12500
6,6.3,6.6,10,11/0.4
15400
64600
0.5
9.0
SC10-16000
16000
Voltage combination(KV)
18900
76000
0.5
9.0
SC10-20000
20000
6,6.3,6.6,10,11/0.4
22400
85500
0.4
10.0
Finally, we also offer a range of monitoring systems that can be used to monitor the temperature of the transformer in real-time. This will allow you to keep an eye on the temperature and take action if necessary.
Overall, we are confident that our enclosed Dry type transformers are equipped with the necessary features to ensure over temperature alarm protection. If you have any further questions, please don’t hesitate to contact us.
Benefits of Using Preinstalled Electrical Substations in Manufacturing Companies In the fast-paced world of manufacturing, efficiency and reliability are key factors…