1. Choose a reliable manufacturer: Make sure to choose a reputable manufacturer with a good track record of producing quality Oil cooled transformers.
2. Regular maintenance: Ensure that regular maintenance is carried out on the transformer, such as checking the oil levels, inspecting the wiring, and cleaning the cooling fins.
3. Use quality parts: Make sure to use quality parts when replacing any components of the transformer.
Type
Rated capacity (KVA)
No-load losses(W)
Voltage combination (KV)
Load losses(W)
No-load current (%)
Short-circuit impedance (%)
S11-M-30
30
100
6,6.3,10,10.5,11/0.4
600
2.3
4.0
S11-M-50
50
130
6,6.3,10,10.5,11/0.4
870
2.0
4.0
S11-M-63
63
150
6,6.3,10,10.5,11/0.4
1040
1.9
4.0
S11-M-80
80
180
6,6.3,10,10.5,11/0.4
1250
1.9
4.0
S11-M-100
100
200
6,6.3,10,10.5,11/0.4
1500
1.8
4.0
S11-M-125
125
240
6,6.3,10,10.5,11/0.4
1800
1.7
4.0
S11-M-160
160
280
6,6.3,10,10.5,11/0.4
2200
1.6
4.0
S11-M-200
200
340
6,6.3,10,10.5,11/0.4
2600
1.5
4.0
S11-M-250
250
400
6,6.3,10,10.5,11/0.4
3050
1.4
4.0
S11-M-315
315
480
6,6.3,10,10.5,11/0.4
3650
1.4
4.0
S11-M-400
400
570
6,6.3,10,10.5,11/0.4
4300
1.3
4.0
S11-M-500
500
680
6,6.3,10,10.5,11/0.4
5100
1.2
4.0
S11-M-630
630
810
6,6.3,10,10.5,11/0.4
6200
1.1
4.5
S11-M-800
800
980
6,6.3,10,10.5,11/0.4
7500
1.0
4.5
S11-M-1000
1000
1150
6,6.3,10,10.5,11/0.4
10300
1.0
4.5
S11-M-1250
1250
1360
6,6.3,10,10.5,11/0.4
12800
0.9
4.5
S11-M-1600
1600
1640
6,6.3,10,10.5,11/0.4
14500
0.8
4.5
S11-M-2000
2000
2280
6,6.3,10,10.5,11/0.4
17820
0.6
5.0
S11-M-2500
2500
2700
6,6.3,10,10.5,11/0.4
20700
0.6
5.0
S11-M-30-
30
90
20,22/0.4
660
2.1
5.5
S11-M-50-
50
130
20,22/0.4
960
2
5.5
S11-M-63-
63
150
20,22/0.4
1145
1.9
5.5
S11-M-80-
80
180
20,22/0.4
1370
1.8
5.5
S11-M-100-
100
200
20,22/0.4
1650
1.6
5.5
S11-M-125-
125
240
20,22/0.4
1980
1.5
5.5
S11-M-160-
160
290
20,22/0.4
2420
1.4
5.5
S11-M-200-
200
330
20,22/0.4
2860
1.3
5.5
S11-M-250-
250
400
20,22/0.4
3350
1.2
5.5
S11-M-315-
315
480
20,22/0.4
4010
1.1
5.5
S11-M-400-
400
570
20,22/0.4
4730
1
5.5
S11-M-500
500
680
20,22/0.4
5660
1
5.5
S11-M-630
630
810
20,22/0.4
6820
0.9
6
S11-M-800
800
980
20,22/0.4
8250
1.8
6
S11-M-1000
1000
1150
20,22/0.4
11330
0.7
6
S11-M-1250
1250
1350
20,22/0.4
13200
0.7
6
S11-M-1600
1600
1630
20,22/0.4
15950
0.6
6
4. Use a qualified technician: Have a qualified technician inspect the transformer regularly to ensure that it is in good working order.
5. Follow the manufacturer’s instructions: Make sure to follow the manufacturer’s instructions for maintenance and operation of the transformer.
Öljymäärän oikea valvonta öljyjäähdytteisessä muuntajassa Öljyjäähdytteisen muuntajan öljytasojen valvonta on tärkeä osa muuntajan oikean toiminnan varmistamista. Öljytasojen asianmukainen seuranta voi auttaa…
Tutustu kiinalaisten valmistajien lämpötilansäädöllä varustettujen Step Down Dry Type -muuntajien etuihin Step down -kuivatyyppiset lämpötilansäädöllä varustetut muuntajat ovat tulossa yhä suositummiksi…
Kiinan valmistajien alumiinikäämityksellä varustettujen ydintyyppisten kuivatyyppisten muuntajien etujen tutkiminen Etsitkö luotettavaa ja kustannustehokasta tapaa tehostaa liiketoimintaasi? Jos näin on, kannattaa harkita…
Arvokkaan nestetyyppisen muuntajatehtaan ja -toimittajan kanssa työskentelyn edut Kun on löydettävä luotettava ja hyvämaineinen nestetyyppinen muuntajatehdas ja -toimittaja, ei ole parempaa…