The Benefits of Installing a Guest House Special Transformer for Fire Prevention and Safety
Installing a guest house special transformer for fire prevention and safety is a great way to ensure the safety of your guests and property. This type of transformer is designed to provide a higher level of protection against fire and other hazards. Here are some of the benefits of installing a guest house special transformer:
1. Increased Fire Protection: The transformer is designed to detect any potential fire hazards and shut off the power supply to the guest house before the fire can spread. This can help to prevent serious damage to the property and any occupants.
2. Improved Safety: The transformer is designed to detect any potential electrical hazards and shut off the power supply to the guest house before any harm can be done. This can help to prevent serious injury or death to any occupants.
3. Reduced Risk of Damage: The transformer is designed to detect any potential electrical faults and shut off the power supply to the guest house before any damage can be done. This can help to reduce the risk of costly repairs or replacements.
4. Increased Efficiency: The transformer is designed to provide a more efficient power supply to the guest house, which can help to reduce energy costs.
Type
Rated capacity (KVA)
Voltage combination(KV)
No-load losses(W)
Load losses(W)
No-load current (%)
Short-circuit impedance (%)
SC10-800
800
33,35,38/6,6.3,6.6,10,11
2200
9400
1.1
6.0
SC10-1000
1000
Voltage combination(KV)
2610
10800
1.1
6.0
SC10-1250
1250
6,6.3,6.6,10,11/0.4
3060
11900
1.0
6.0
SC10-1500
1500
Voltage combination(KV)
3600
15400
1.0
6.0
SC10-2000
2000
6,6.3,6.6,10,11/0.4
4130
18200
0.9
7.0
SC10-2500
2500
Voltage combination(KV)
4750
21800
0.9
7.0
SC10-3150
3150
6,6.3,6.6,10,11/0.4
5880
24500
0.8
8.0
SC10-4000
4000
Voltage combination(KV)
6860
29400
0.8
8.0
SC10-5000
5000
6,6.3,6.6,10,11/0.4
8180
34960
0.7
8.0
SC10-6300
6300
Voltage combination(KV)
9680
40800
0.7
8.0
SC10-8000
8000
6,6.3,6.6,10,11/0.4
11000
46060
0.6
9.0
SC10-10000
10000
Voltage combination(KV)
12660
56500
0.6
9.0
SC10-12500
12500
6,6.3,6.6,10,11/0.4
15400
64600
0.5
9.0
SC10-16000
16000
Voltage combination(KV)
18900
76000
0.5
9.0
SC10-20000
20000
6,6.3,6.6,10,11/0.4
22400
85500
0.4
10.0
Installing a guest house special transformer for fire prevention and safety is a great way to ensure the safety of your guests and property. This type of transformer can provide increased fire protection, improved safety, reduced risk of damage, and increased efficiency.