The IEC60076 standard is an international standard for the design and construction of Liquid cooled transformers. It is a comprehensive set of guidelines that ensure the quality and safety of these transformers. This standard is essential for the safe and reliable operation of Liquid cooled transformers, and it is important to understand the benefits of this standard.
Type
Rated capacity (KVA)
Voltage combination(KV)
No-load losses(W)
Load losses(W)
No-load current (%)
Short-circuit impedance (%)
S11-630
630
33,35/6.3,6.6,10.5,11
830
7870
1.10
6.5
S11-800
800
33,35/6.3,6.6,10.5,11
980
9410
1.00
6.5
S11-1000
1000
33,35/6.3,6.6,10.5,11
1150
11540
1.00
6.5
S11-1250
1250
33,35/6.3,6.6,10.5,11
1410
13940
0.90
6.5
S11-1600
1600
33,35/6.3,6.6,10.5,11
1700
16670
0.80
6.5
S11-2000
2000
33,35/6.3,6.6,10.5,11
2180
18380
0.70
6.5
S11-2500
2500
33,35/6.3,6.6,10.5,11
2560
19670
0.60
6.5
S11-3150
3150
33,35/6.3,6.6,10.5,11
3040
23090
0.56
7.0
S11-4000
4000
33,35/6.3,6.6,10.5,11
3620
27360
0.56
7.0
S11-5000
5000
33,35/6.3,6.6,10.5,11
4320
31380
0.48
7.0
S11-6300
6300
33,35/6.3,6.6,10.5,11
5250
35060
0.48
7.5
S11-8000
8000
33,35/6.3,6.6,10.5,11
7200
38500
0.42
7.5
S11-10000
10000
33,35/6.3,6.6,10.5,11
8700
45300
0.42
7.5
S11-12500
12500
33,35/6.3,6.6,10.5,11
10080
53900
0.40
8.0
S11-16000
16000
33,35/6.3,6.6,10.5,11
12160
65800
0.40
8.0
S11-20000
20000
33,35/6.3,6.6,10.5,11
14400
79500
0.40
8.0
S11-25000
25000
33,35/6.3,6.6,10.5,11
17020
94100
0.32
8.0
S11-31500
31500
33,35/6.3,6.6,10.5,11
20220
112900
0.32
8.0
Liquid cooled transformers are used in a variety of applications, from industrial to residential. They are designed to provide a reliable source of power and are often used in high-voltage applications. The IEC60076 standard ensures that these transformers are designed and constructed to the highest quality and safety standards.
The IEC60076 standard covers a wide range of topics, from design and construction to testing and maintenance. It outlines the requirements for the design and construction of Liquid cooled transformers, including the materials used, the insulation system, and the cooling system. It also outlines the requirements for testing and maintenance, including the testing of the transformer’s insulation system and the maintenance of the cooling system.
The IEC60076 standard ensures that Liquid cooled transformers are designed and constructed to the highest quality and safety standards. This standard ensures that the transformer is designed to withstand the high voltage and current levels that it will be exposed to. It also ensures that the transformer is constructed with the highest quality materials and components, and that the insulation system is designed to protect against electrical shock and fire hazards.
The IEC60076 standard also ensures that the transformer is tested and maintained properly. This includes testing the insulation system to ensure that it is functioning properly and that it is able to withstand the high voltage and current levels that it will be exposed to. It also includes the maintenance of the cooling system to ensure that it is functioning properly and that it is able to keep the transformer cool.
The IEC60076 standard is essential for the safe and reliable operation of Liquid cooled transformers. It ensures that these transformers are designed and constructed to the highest quality and safety standards, and that they are tested and maintained properly. This standard is essential for the safe and reliable operation of Liquid cooled transformers, and it is important to understand the benefits of this standard.
Understanding the Manufacturing Process of Liquid cooled transformers: What to Look for in a Quality Manufacturer