As large-scale manufacturing companies continue to expand their operations, they must consider the most efficient and cost-effective solutions for their power needs. One such solution is the use of Liquid immersed transformers. This type of transformer offers a number of advantages over traditional air-cooled transformers, making them an attractive option for large-scale manufacturing companies.
Type
Rated capacity (KVA)
No-load losses(W)
Voltage combination (KV)
Load losses(W)
No-load current (%)
Short-circuit impedance (%)
S11-M-30
30
100
6,6.3,10,10.5,11/0.4
600
2.3
4.0
S11-M-50
50
130
6,6.3,10,10.5,11/0.4
870
2.0
4.0
S11-M-63
63
150
6,6.3,10,10.5,11/0.4
1040
1.9
4.0
S11-M-80
80
180
6,6.3,10,10.5,11/0.4
1250
1.9
4.0
S11-M-100
100
200
6,6.3,10,10.5,11/0.4
1500
1.8
4.0
S11-M-125
125
240
6,6.3,10,10.5,11/0.4
1800
1.7
4.0
S11-M-160
160
280
6,6.3,10,10.5,11/0.4
2200
1.6
4.0
S11-M-200
200
340
6,6.3,10,10.5,11/0.4
2600
1.5
4.0
S11-M-250
250
400
6,6.3,10,10.5,11/0.4
3050
1.4
4.0
S11-M-315
315
480
6,6.3,10,10.5,11/0.4
3650
1.4
4.0
S11-M-400
400
570
6,6.3,10,10.5,11/0.4
4300
1.3
4.0
S11-M-500
500
680
6,6.3,10,10.5,11/0.4
5100
1.2
4.0
S11-M-630
630
810
6,6.3,10,10.5,11/0.4
6200
1.1
4.5
S11-M-800
800
980
6,6.3,10,10.5,11/0.4
7500
1.0
4.5
S11-M-1000
1000
1150
6,6.3,10,10.5,11/0.4
10300
1.0
4.5
S11-M-1250
1250
1360
6,6.3,10,10.5,11/0.4
12800
0.9
4.5
S11-M-1600
1600
1640
6,6.3,10,10.5,11/0.4
14500
0.8
4.5
S11-M-2000
2000
2280
6,6.3,10,10.5,11/0.4
17820
0.6
5.0
S11-M-2500
2500
2700
6,6.3,10,10.5,11/0.4
20700
0.6
5.0
S11-M-30-
30
90
20,22/0.4
660
2.1
5.5
S11-M-50-
50
130
20,22/0.4
960
2
5.5
S11-M-63-
63
150
20,22/0.4
1145
1.9
5.5
S11-M-80-
80
180
20,22/0.4
1370
1.8
5.5
S11-M-100-
100
200
20,22/0.4
1650
1.6
5.5
S11-M-125-
125
240
20,22/0.4
1980
1.5
5.5
S11-M-160-
160
290
20,22/0.4
2420
1.4
5.5
S11-M-200-
200
330
20,22/0.4
2860
1.3
5.5
S11-M-250-
250
400
20,22/0.4
3350
1.2
5.5
S11-M-315-
315
480
20,22/0.4
4010
1.1
5.5
S11-M-400-
400
570
20,22/0.4
4730
1
5.5
S11-M-500
500
680
20,22/0.4
5660
1
5.5
S11-M-630
630
810
20,22/0.4
6820
0.9
6
S11-M-800
800
980
20,22/0.4
8250
1.8
6
S11-M-1000
1000
1150
20,22/0.4
11330
0.7
6
S11-M-1250
1250
1350
20,22/0.4
13200
0.7
6
S11-M-1600
1600
1630
20,22/0.4
15950
0.6
6
To begin with, Liquid immersed transformers are more efficient than air-cooled transformers. This is because the liquid coolant used in these transformers is able to absorb more heat than air, allowing the transformer to operate at higher temperatures without compromising its performance. This increased efficiency translates into lower energy costs for the company, as well as reduced maintenance costs.
In addition, Liquid immersed transformers are more reliable than air-cooled transformers. This is because the liquid coolant used in these transformers is able to absorb more heat than air, allowing the transformer to operate at higher temperatures without compromising its performance. This increased reliability translates into fewer breakdowns and less downtime for the company, resulting in increased productivity and profitability.
Finally, Liquid immersed transformers are more environmentally friendly than air-cooled transformers. This is because the liquid coolant used in these transformers is non-toxic and does not release any harmful emissions into the atmosphere. This makes them a much more sustainable option for large-scale manufacturing companies, as they can help reduce their carbon footprint and contribute to a healthier environment.
Overall, Liquid immersed transformers offer a number of advantages over traditional air-cooled transformers, making them an attractive option for large-scale manufacturing companies. With their increased efficiency, reliability, and environmental friendliness, these transformers can help companies reduce their energy costs, increase their productivity, and contribute to a healthier environment.
How Customized Dry type transformers Can Help Your Manufacturing Company Meet IEC60076 Standards As a manufacturing company, you understand the importance…