Are you looking for a way to improve the no-load voltage regulation of your electrical system? If so, you may want to consider using Liquid immersed transformers. These transformers are designed to provide superior no-load voltage regulation compared to traditional dry-type transformers.
Type
Rated capacity (KVA)
Voltage combination(KV)
No-load losses(W)
Load losses(W)
No-load Current (%)
Short-circuit impedance (%)
SH15-M-30
30
6,6.3,10,10.5,11/0.4
33
630
1.50
4.0
SH15-M-50
50
6,6.3,10,10.5,11/0.4
43
910
1.20
4.0
SH15-M-63
63
6,6.3,10,10.5,11/0.4
50
1090
1.10
4.0
SH15-M-80
80
6,6.3,10,10.5,11/0.4
60
1310
1.00
4.0
SH15-M-100
100
6,6.3,10,10.5,11/0.4
75
1580
0.90
4.0
SH15-M-125
125
6,6.3,10,10.5,11/0.4
85
1890
0.80
4.0
SH15-M-160
160
6,6.3,10,10.5,11/0.4
100
2310
0.60
4.0
SH15-M-200
200
6,6.3,10,10.5,11/0.4
120
2730
0.60
4.0
SH15-M-250
250
6,6.3,10,10.5,11/0.4
140
3200
0.60
4.0
SH15-M-315
315
6,6.3,10,10.5,11/0.4
170
3830
0.50
4.0
SH15-M-400
400
6,6.3,10,10.5,11/0.4
200
4520
0.50
4.0
SH15-M-500
500
6,6.3,10,10.5,11/0.4
240
5140
0.50
4.0
SH15-M-630
630
6,6.3,10,10.5,11/0.4
320
6200
0.30
4.5
SH15-M-800
800
6,6.3,10,10.5,11/0.4
380
7500
0.30
4.5
SH15-M-1000
1000
6,6.3,10,10.5,11/0.4
450
10300
0.30
4.5
SH15-M-1250
1250
6,6.3,10,10.5,11/0.4
530
12000
0.20
4.5
SH15-M-1600
1600
6,6.3,10,10.5,11/0.4
630
14500
0.20
4.5
SH15-M-2000
2000
6,6.3,10,10.5,11/0.4
750
18300
0.20
5.0
SH15-M-2500
2500
6,6.3,10,10.5,11/0.4
900
21200
0.20
5.0
Liquid immersed transformers are filled with a dielectric fluid, such as mineral oil, which helps to reduce the temperature of the transformer and improve its efficiency. This fluid also helps to reduce the amount of noise generated by the transformer, making it quieter and more efficient.
The liquid also helps to reduce the amount of voltage drop that occurs when the transformer is operating at no-load. This is because the liquid helps to reduce the amount of resistance in the transformer, allowing it to maintain a more consistent voltage output.
Another benefit of Liquid immersed transformers is that they are more reliable than dry-type transformers. This is because the liquid helps to protect the transformer from damage caused by moisture, dust, and other contaminants. This makes them less likely to fail and more reliable in the long run.
Finally, Liquid immersed transformers are more cost-effective than dry-type transformers. This is because they require less maintenance and are more efficient, resulting in lower energy costs.
Overall, Liquid immersed transformers offer many benefits for no-load voltage regulation. They are more reliable, quieter, and more cost-effective than dry-type transformers. If you are looking for a way to improve the no-load voltage regulation of your electrical system, you may want to consider using Liquid immersed transformers.