When it comes to medium voltage Dry type transformers from China manufacturers, the benefits of automatic fan start and stop are undeniable. As a facility manager, I have seen firsthand how this technology can help reduce energy costs and improve the overall efficiency of the transformer. The first benefit of automatic fan start and stop is that it helps to reduce energy costs. By automatically starting and stopping the fan when needed, the transformer is able to operate more efficiently and use less energy. This can result in significant savings on energy bills. Additionally, the fan will only run when it is needed, which helps to reduce wear and tear on the transformer and its components. The second benefit of automatic fan start and stop is that it helps to improve the overall efficiency of the transformer. By automatically starting and stopping the fan when needed, the transformer is able to operate more efficiently and use less energy. This can result in improved performance and increased reliability. Additionally, the fan will only run when it is needed, which helps to reduce wear and tear on the transformer and its components. Finally, the third benefit of automatic fan start and stop is that it helps to reduce maintenance costs. By automatically starting and stopping the fan when needed, the transformer is able to operate more efficiently and use less energy. This can result in fewer maintenance costs, as the fan will only run when it is needed. Additionally, the fan will only run when it is needed, which helps to reduce wear and tear on the transformer and its components.
TypeRated capacity (KVA)Voltage combination(KV)No-load losses(W)Load losses(W)No-load current (%)Short-circuit impedance (%)
SC12-30306,6.3,6.6,10,11/0.41507102.04.0
SC12-50506,6.3,6.6,10,11/0.421510002.04.0
SC12-80806,6.3,6.6,10,11/0.429513801.54.0
SC12-1001006,6.3,6.6,10,11/0.432015701.54.0
SC12-1251256,6.3,6.6,10,11/0.437518501.34.0
SCB12-1601606,6.3,6.6,10,11/0.443021301.34.0
SCB12-2002006,6.3,6.6,10,11/0.449525301.14.0
SCB12-2502506,6.3,6.6,10,11/0.457527601.14.0
SCB12-3153156,6.3,6.6,10,11/0.470534701.04.0
SCB12-4004006,6.3,6.6,10,11/0.478539901.04.0
SCB12-5005006,6.3,6.6,10,11/0.493048801.04.0
SCB12-6306306,6.3,6.6,10,11/0.4107058800.854.0
SCB12-6306306,6.3,6.6,10,11/0.4104059600.856.0
SCB12-8008006,6.3,6.6,10,11/0.4121069600.856.0
SCB12-100010006,6.3,6.6,10,11/0.4141081300.856.0
SCB12-125012506,6.3,6.6,10,11/0.4167096900.856.0
SCB12-160016006,6.3,6.6,10,11/0.41960117000.856.0
SCB12-200020006,6.3,6.6,10,11/0.42440144000.76.0
SCB12-250025006,6.3,6.6,10,11/0.42880171000.76.0
Overall, the benefits of automatic fan start and stop for medium voltage Dry type transformers from China manufacturers are clear. By automatically starting and stopping the fan when needed, the transformer is able to operate more efficiently and use less energy. This can result in significant savings on energy bills, improved performance and increased reliability, and reduced maintenance costs. As a facility manager, I highly recommend investing in this technology for your medium voltage Dry type transformers.