Exploring the Benefits of Automatic Fan Start and Stop for Medium Voltage Dry type transformers from China Manufacturers
When it comes to medium voltage Dry type transformers from China manufacturers, the benefits of automatic fan start and stop are undeniable. As a facility manager, I have seen firsthand how this technology can help reduce energy costs and improve the overall efficiency of the transformer.
The first benefit of automatic fan start and stop is that it helps to reduce energy costs. By automatically starting and stopping the fan when needed, the transformer is able to operate more efficiently and use less energy. This can result in significant savings on energy bills. Additionally, the fan will only run when it is needed, which helps to reduce wear and tear on the transformer and its components.
The second benefit of automatic fan start and stop is that it helps to improve the overall efficiency of the transformer. By automatically starting and stopping the fan when needed, the transformer is able to operate more efficiently and use less energy. This can result in improved performance and increased reliability. Additionally, the fan will only run when it is needed, which helps to reduce wear and tear on the transformer and its components.
Finally, the third benefit of automatic fan start and stop is that it helps to reduce maintenance costs. By automatically starting and stopping the fan when needed, the transformer is able to operate more efficiently and use less energy. This can result in fewer maintenance costs, as the fan will only run when it is needed. Additionally, the fan will only run when it is needed, which helps to reduce wear and tear on the transformer and its components.
Type
Rated capacity (KVA)
Voltage combination(KV)
No-load losses(W)
Load losses(W)
No-load current (%)
Short-circuit impedance (%)
SC12-30
30
6,6.3,6.6,10,11/0.4
150
710
2.0
4.0
SC12-50
50
6,6.3,6.6,10,11/0.4
215
1000
2.0
4.0
SC12-80
80
6,6.3,6.6,10,11/0.4
295
1380
1.5
4.0
SC12-100
100
6,6.3,6.6,10,11/0.4
320
1570
1.5
4.0
SC12-125
125
6,6.3,6.6,10,11/0.4
375
1850
1.3
4.0
SCB12-160
160
6,6.3,6.6,10,11/0.4
430
2130
1.3
4.0
SCB12-200
200
6,6.3,6.6,10,11/0.4
495
2530
1.1
4.0
SCB12-250
250
6,6.3,6.6,10,11/0.4
575
2760
1.1
4.0
SCB12-315
315
6,6.3,6.6,10,11/0.4
705
3470
1.0
4.0
SCB12-400
400
6,6.3,6.6,10,11/0.4
785
3990
1.0
4.0
SCB12-500
500
6,6.3,6.6,10,11/0.4
930
4880
1.0
4.0
SCB12-630
630
6,6.3,6.6,10,11/0.4
1070
5880
0.85
4.0
SCB12-630
630
6,6.3,6.6,10,11/0.4
1040
5960
0.85
6.0
SCB12-800
800
6,6.3,6.6,10,11/0.4
1210
6960
0.85
6.0
SCB12-1000
1000
6,6.3,6.6,10,11/0.4
1410
8130
0.85
6.0
SCB12-1250
1250
6,6.3,6.6,10,11/0.4
1670
9690
0.85
6.0
SCB12-1600
1600
6,6.3,6.6,10,11/0.4
1960
11700
0.85
6.0
SCB12-2000
2000
6,6.3,6.6,10,11/0.4
2440
14400
0.7
6.0
SCB12-2500
2500
6,6.3,6.6,10,11/0.4
2880
17100
0.7
6.0
Overall, the benefits of automatic fan start and stop for medium voltage Dry type transformers from China manufacturers are clear. By automatically starting and stopping the fan when needed, the transformer is able to operate more efficiently and use less energy. This can result in significant savings on energy bills, improved performance and increased reliability, and reduced maintenance costs. As a facility manager, I highly recommend investing in this technology for your medium voltage Dry type transformers.