As a China manufacturer, it is important to understand the type tests for Oil immersed transformers. These tests are designed to ensure that the transformer meets the required safety and performance standards. In this guide, we will explain the different types of tests and how they are used to evaluate the quality of the transformer.
The first type of test is the dielectric test. This test is used to measure the insulation resistance of the transformer. It is done by applying a high voltage to the transformer and measuring the current that flows through it. The higher the insulation resistance, the better the transformer will be able to withstand electrical shocks and other hazards.
The second type of test is the short-circuit test. This test is used to measure the ability of the transformer to withstand short-circuits. It is done by applying a high current to the transformer and measuring the voltage that is generated. The higher the voltage, the better the transformer will be able to withstand short-circuits.
The third type of test is the temperature rise test. This test is used to measure the temperature rise of the transformer when it is operating. It is done by measuring the temperature of the transformer at different points in its operation. The higher the temperature rise, the better the transformer will be able to withstand high temperatures.
Finally, the fourth type of test is the overload test. This test is used to measure the ability of the transformer to withstand overloads. It is done by applying a high current to the transformer and measuring the voltage that is generated. The higher the voltage, the better the transformer will be able to withstand overloads.
Type
Rated capacity (KVA)
No-load losses(W)
Voltage combination (KV)
Load losses(W)
No-load current (%)
Short-circuit impedance (%)
S11-M-30
30
100
6,6.3,10,10.5,11/0.4
600
2.3
4.0
S11-M-50
50
130
6,6.3,10,10.5,11/0.4
870
2.0
4.0
S11-M-63
63
150
6,6.3,10,10.5,11/0.4
1040
1.9
4.0
S11-M-80
80
180
6,6.3,10,10.5,11/0.4
1250
1.9
4.0
S11-M-100
100
200
6,6.3,10,10.5,11/0.4
1500
1.8
4.0
S11-M-125
125
240
6,6.3,10,10.5,11/0.4
1800
1.7
4.0
S11-M-160
160
280
6,6.3,10,10.5,11/0.4
2200
1.6
4.0
S11-M-200
200
340
6,6.3,10,10.5,11/0.4
2600
1.5
4.0
S11-M-250
250
400
6,6.3,10,10.5,11/0.4
3050
1.4
4.0
S11-M-315
315
480
6,6.3,10,10.5,11/0.4
3650
1.4
4.0
S11-M-400
400
570
6,6.3,10,10.5,11/0.4
4300
1.3
4.0
S11-M-500
500
680
6,6.3,10,10.5,11/0.4
5100
1.2
4.0
S11-M-630
630
810
6,6.3,10,10.5,11/0.4
6200
1.1
4.5
S11-M-800
800
980
6,6.3,10,10.5,11/0.4
7500
1.0
4.5
S11-M-1000
1000
1150
6,6.3,10,10.5,11/0.4
10300
1.0
4.5
S11-M-1250
1250
1360
6,6.3,10,10.5,11/0.4
12800
0.9
4.5
S11-M-1600
1600
1640
6,6.3,10,10.5,11/0.4
14500
0.8
4.5
S11-M-2000
2000
2280
6,6.3,10,10.5,11/0.4
17820
0.6
5.0
S11-M-2500
2500
2700
6,6.3,10,10.5,11/0.4
20700
0.6
5.0
S11-M-30-
30
90
20,22/0.4
660
2.1
5.5
S11-M-50-
50
130
20,22/0.4
960
2
5.5
S11-M-63-
63
150
20,22/0.4
1145
1.9
5.5
S11-M-80-
80
180
20,22/0.4
1370
1.8
5.5
S11-M-100-
100
200
20,22/0.4
1650
1.6
5.5
S11-M-125-
125
240
20,22/0.4
1980
1.5
5.5
S11-M-160-
160
290
20,22/0.4
2420
1.4
5.5
S11-M-200-
200
330
20,22/0.4
2860
1.3
5.5
S11-M-250-
250
400
20,22/0.4
3350
1.2
5.5
S11-M-315-
315
480
20,22/0.4
4010
1.1
5.5
S11-M-400-
400
570
20,22/0.4
4730
1
5.5
S11-M-500
500
680
20,22/0.4
5660
1
5.5
S11-M-630
630
810
20,22/0.4
6820
0.9
6
S11-M-800
800
980
20,22/0.4
8250
1.8
6
S11-M-1000
1000
1150
20,22/0.4
11330
0.7
6
S11-M-1250
1250
1350
20,22/0.4
13200
0.7
6
S11-M-1600
1600
1630
20,22/0.4
15950
0.6
6
By understanding the different types of tests for Oil immersed transformers, China manufacturers can ensure that their products meet the required safety and performance standards. This guide has provided an overview of the different types of tests and how they are used to evaluate the quality of the transformer.