The power industry is being revolutionized by the introduction of resin insulated dry type transformers. These transformers are designed to provide reliable and efficient power distribution, while also being safer and more environmentally friendly than traditional oil-filled transformers. Resin insulated dry type transformers are made with a combination of resin and insulation materials, which are then molded into a single unit. This design eliminates the need for oil, which can be hazardous and can cause environmental damage if it leaks. The resin insulation also helps to reduce the risk of fire, as it is self-extinguishing and does not require additional fire protection. The resin insulation also helps to reduce noise levels, making them ideal for use in residential and commercial areas. They are also more efficient than traditional oil-filled transformers, as they require less energy to operate. This means that they can help to reduce energy costs for businesses and households. Resin insulated dry type transformers are also more reliable than traditional oil-filled transformers, as they are designed to withstand extreme temperatures and environmental conditions. This makes them ideal for use in areas where temperatures can fluctuate, such as in desert climates.
Type
Rated capacity (KVA)
Voltage combination(KV)
No-load losses(W)
Load losses(W)
No-load current (%)
Short-circuit impedance (%)
SCH15-30
30
6,6.3,6.6,10,11/0.4
70
710
1.6
4.0
SCH15-50
50
6,6.3,6.6,10,11/0.4
90
1000
1.4
4.0
SCH15-80
80
6,6.3,6.6,10,11/0.4
120
1380
1.3
4.0
SCH15-100
100
6,6.3,6.6,10,11/0.4
130
1570
1.2
4.0
SCH15-125
125
6,6.3,6.6,10,11/0.4
150
1850
1.1
4.0
SC(B)H15-160
160
6,6.3,6.6,10,11/0.4
170
2130
1.1
4.0
SC(B)H15-200
200
6,6.3,6.6,10,11/0.4
200
2530
1.0
4.0
SC(B)H15-250
250
6,6.3,6.6,10,11/0.4
230
2760
1.0
4.0
SC(B)H15-315
315
6,6.3,6.6,10,11/0.4
280
3470
0.9
4.0
SC(B)H15-400
400
6,6.3,6.6,10,11/0.4
310
3990
0.8
4.0
SC(B)H15-500
500
6,6.3,6.6,10,11/0.4
360
4880
0.8
4.0
SC(B)H15-630
630
6,6.3,6.6,10,11/0.4
420
5880
0.7
4.0
SC(B)H15-630
630
6,6.3,6.6,10,11/0.4
410
5960
0.7
6.0
SC(B)H15-800
800
6,6.3,6.6,10,11/0.4
480
6960
0.7
6.0
SC(B)H15-1000
1000
6,6.3,6.6,10,11/0.4
550
8130
0.6
6.0
SC(B)H15-1250
1250
6,6.3,6.6,10,11/0.4
650
9690
0.6
6.0
SC(B)H15-1600
1600
6,6.3,6.6,10,11/0.4
780
11730
0.6
6.0
SC(B)H15-2000
2000
6,6.3,6.6,10,11/0.4
1000
14450
0.5
6.0
SC(B)H15-2500
2500
6,6.3,6.6,10,11/0.4
1200
17170
0.5
6.0
Overall, resin insulated dry type transformers are revolutionizing the power industry by providing a safer, more efficient, and more reliable power distribution solution. They are also helping to reduce energy costs and environmental damage, making them a great choice for businesses and households alike.
The Benefits of Automatic Trip Technology for Resin Insulated Dry Type Transformers
Automatic trip technology for resin insulated dry type transformers offers a number of benefits for businesses and homeowners alike. This technology helps to protect transformers from overloads, short circuits, and other potential hazards. Here are some of the key benefits of using automatic trip technology for resin insulated dry type transformers:
1. Increased Safety: Automatic trip technology helps to ensure that transformers are protected from overloads and short circuits, which can be dangerous and cause costly damage. This technology helps to reduce the risk of fire and other safety hazards. 2. Improved Efficiency: Automatic trip technology helps to ensure that transformers are operating at their optimal efficiency. This helps to reduce energy costs and improve the overall performance of the transformer. 3. Reduced Maintenance: Automatic trip technology helps to reduce the need for regular maintenance and repairs. This helps to save time and money, as well as reduce the risk of unexpected downtime.
Type
Rated capacity (KVA)
Voltage combination(KV)
No-load losses(W)
Load losses(W)
No-load Current (%)
Short-circuit impedance (%)
SH15-M-30
30
6,6.3,10,10.5,11/0.4
33
630
1.50
4.0
SH15-M-50
50
6,6.3,10,10.5,11/0.4
43
910
1.20
4.0
SH15-M-63
63
6,6.3,10,10.5,11/0.4
50
1090
1.10
4.0
SH15-M-80
80
6,6.3,10,10.5,11/0.4
60
1310
1.00
4.0
SH15-M-100
100
6,6.3,10,10.5,11/0.4
75
1580
0.90
4.0
SH15-M-125
125
6,6.3,10,10.5,11/0.4
85
1890
0.80
4.0
SH15-M-160
160
6,6.3,10,10.5,11/0.4
100
2310
0.60
4.0
SH15-M-200
200
6,6.3,10,10.5,11/0.4
120
2730
0.60
4.0
SH15-M-250
250
6,6.3,10,10.5,11/0.4
140
3200
0.60
4.0
SH15-M-315
315
6,6.3,10,10.5,11/0.4
170
3830
0.50
4.0
SH15-M-400
400
6,6.3,10,10.5,11/0.4
200
4520
0.50
4.0
SH15-M-500
500
6,6.3,10,10.5,11/0.4
240
5140
0.50
4.0
SH15-M-630
630
6,6.3,10,10.5,11/0.4
320
6200
0.30
4.5
SH15-M-800
800
6,6.3,10,10.5,11/0.4
380
7500
0.30
4.5
SH15-M-1000
1000
6,6.3,10,10.5,11/0.4
450
10300
0.30
4.5
SH15-M-1250
1250
6,6.3,10,10.5,11/0.4
530
12000
0.20
4.5
SH15-M-1600
1600
6,6.3,10,10.5,11/0.4
630
14500
0.20
4.5
SH15-M-2000
2000
6,6.3,10,10.5,11/0.4
750
18300
0.20
5.0
SH15-M-2500
2500
6,6.3,10,10.5,11/0.4
900
21200
0.20
5.0
4. Increased Reliability: Automatic trip technology helps to ensure that transformers are reliable and can handle the demands of their environment. This helps to reduce the risk of unexpected downtime and improve the overall performance of the transformer. Overall, automatic trip technology for resin insulated dry type transformers offers a number of benefits for businesses and homeowners alike. This technology helps to ensure that transformers are safe, efficient, reliable, and require less maintenance. If you’re looking for a way to improve the performance of your transformer, automatic trip technology is a great option.