The Benefits of Resin Insulation Dry type transformers for Fire Safety in Manufacturing Facilities

Resin insulation Dry type transformers are an ideal choice for fire safety in manufacturing facilities. These transformers are designed to be completely sealed, eliminating the risk of fire caused by oil leakage. Additionally, the resin insulation used in these transformers is self-extinguishing, meaning that it will not support combustion. This makes them an ideal choice for facilities where fire safety is a priority. alt-901 The resin insulation used in these transformers also provides superior electrical insulation, which helps to reduce the risk of electrical shock. This is especially important in manufacturing facilities, where workers are often exposed to high voltage equipment. The insulation also helps to reduce the risk of electrical fires, as it prevents the buildup of heat and arcing.
The sealed design of resin insulation Dry type transformers also helps to reduce the risk of fire spreading. In the event of a fire, the transformer will contain the flames, preventing them from spreading to other areas of the facility. This is especially important in manufacturing facilities, where the presence of combustible materials can quickly lead to a large-scale fire. Finally, resin insulation Dry type transformers are also more cost-effective than other types of transformers. This is because they require less maintenance and are more energy efficient. This helps to reduce operational costs, making them an ideal choice for manufacturing facilities. In conclusion, resin insulation Dry type transformers are an ideal choice for fire safety in manufacturing facilities. They are designed to be completely sealed, eliminating the risk of fire caused by oil leakage. Additionally, the resin insulation used in these transformers is self-extinguishing, providing superior electrical insulation and reducing the risk of electrical shock and fire. The sealed design also helps to contain fires, preventing them from spreading to other areas of the facility. Finally, these transformers are more cost-effective than other types of transformers, helping to reduce operational costs.
TypeRated capacity (KVA)Voltage combination(KV)No-load losses(W)Load losses(W)No-load current (%)Short-circuit impedance (%)
SC12-30306,6.3,6.6,10,11/0.41507102.04.0
SC12-50506,6.3,6.6,10,11/0.421510002.04.0
SC12-80806,6.3,6.6,10,11/0.429513801.54.0
SC12-1001006,6.3,6.6,10,11/0.432015701.54.0
SC12-1251256,6.3,6.6,10,11/0.437518501.34.0
SCB12-1601606,6.3,6.6,10,11/0.443021301.34.0
SCB12-2002006,6.3,6.6,10,11/0.449525301.14.0
SCB12-2502506,6.3,6.6,10,11/0.457527601.14.0
SCB12-3153156,6.3,6.6,10,11/0.470534701.04.0
SCB12-4004006,6.3,6.6,10,11/0.478539901.04.0
SCB12-5005006,6.3,6.6,10,11/0.493048801.04.0
SCB12-6306306,6.3,6.6,10,11/0.4107058800.854.0
SCB12-6306306,6.3,6.6,10,11/0.4104059600.856.0
SCB12-8008006,6.3,6.6,10,11/0.4121069600.856.0
SCB12-100010006,6.3,6.6,10,11/0.4141081300.856.0
SCB12-125012506,6.3,6.6,10,11/0.4167096900.856.0
SCB12-160016006,6.3,6.6,10,11/0.41960117000.856.0
SCB12-200020006,6.3,6.6,10,11/0.42440144000.76.0
SCB12-250025006,6.3,6.6,10,11/0.42880171000.76.0