How Resin Insulation Dry type transformers Meet IEC60076 Standards

Person 1: How do resin insulation Dry type transformers meet IEC60076 standards? alt-870 Person 2: Resin insulation Dry type transformers must meet the requirements of IEC60076, which is the international standard for Power transformers. The standard covers the design, manufacture, testing, and operation of Power transformers. To meet the standard, the transformer must have a high-quality insulation system, a reliable cooling system, and a robust construction. The insulation system must be able to withstand the electrical and thermal stresses of the transformer’s operation. The cooling system must be able to dissipate the heat generated by the transformer’s operation. The construction must be able to withstand the mechanical stresses of the transformer’s operation. Additionally, the transformer must be tested to ensure that it meets the requirements of the standard.

The Benefits of Working with a Reputable Resin Insulation Dry type transformer Factory and Supplier

Customer: “What are the benefits of working with a reputable resin insulation Dry type transformer factory and supplier?”
Supplier: “There are many benefits to working with a reputable resin insulation Dry type transformer factory and supplier. First, you can be sure that the products you receive are of the highest quality. The factory and supplier will use the latest technology and materials to ensure that the transformers are reliable and efficient. Additionally, the factory and supplier will have a team of experienced engineers and technicians who can provide technical support and advice. Finally, the factory and supplier will have a wide range of products to choose from, so you can find the perfect transformer for your needs.”
TypeRated capacity (KVA)Voltage combination(KV)No-load losses(W)Load losses(W)No-load current (%)Short-circuit impedance (%)
SC10-80080033,35,38/6,6.3,6.6,10,11220094001.16.0
SC10-10001000Voltage combination(KV)2610108001.16.0
SC10-125012506,6.3,6.6,10,11/0.43060119001.06.0
SC10-15001500Voltage combination(KV)3600154001.06.0
SC10-200020006,6.3,6.6,10,11/0.44130182000.97.0
SC10-25002500Voltage combination(KV)4750218000.97.0
SC10-315031506,6.3,6.6,10,11/0.45880245000.88.0
SC10-40004000Voltage combination(KV)6860294000.88.0
SC10-500050006,6.3,6.6,10,11/0.48180349600.78.0
SC10-63006300Voltage combination(KV)9680408000.78.0
SC10-800080006,6.3,6.6,10,11/0.411000460600.69.0
SC10-1000010000Voltage combination(KV)12660565000.69.0
SC10-12500125006,6.3,6.6,10,11/0.415400646000.59.0
SC10-1600016000Voltage combination(KV)18900760000.59.0
SC10-20000200006,6.3,6.6,10,11/0.422400855000.410.0

Similar Posts