Sealed type oil immersed transformers are becoming increasingly popular in lot production and manufacturing due to their many benefits. These transformers are designed to be completely sealed, meaning that they are not exposed to the environment and are therefore protected from dust, moisture, and other contaminants. This makes them ideal for use in production and manufacturing, as they are less likely to be damaged or require maintenance. The sealed design also helps to reduce noise levels, as the transformer is not exposed to the environment. This is especially beneficial in production and manufacturing, as it helps to reduce the amount of noise pollution in the workplace. Additionally, the sealed design helps to reduce the risk of fire, as the transformer is not exposed to the environment and is therefore less likely to be damaged by sparks or other sources of ignition. The sealed design also helps to improve the efficiency of the transformer, as it is not exposed to the environment and therefore does not require additional cooling. This helps to reduce energy costs, as the transformer does not need to be cooled in order to operate efficiently. Additionally, the sealed design helps to reduce the risk of electrical shock, as the transformer is not exposed to the environment and therefore does not require additional insulation. alt-695 Finally, sealed type oil immersed transformers are also more reliable than other types of transformers, as they are not exposed to the environment and therefore are less likely to be damaged or require maintenance. This makes them ideal for use in production and manufacturing, as they are less likely to fail or require repairs.
Overall, sealed type oil immersed transformers are becoming increasingly popular in lot production and manufacturing due to their many benefits. They are designed to be completely sealed, meaning that they are not exposed to the environment and are therefore protected from dust, moisture, and other contaminants. Additionally, the sealed design helps to reduce noise levels, improve efficiency, and reduce the risk of fire and electrical shock. Finally, they are also more reliable than other types of transformers, making them ideal for use in production and manufacturing.
TypeRated capacity (KVA)No-load losses(W)Voltage combination (KV)Load losses(W)No-load current (%)Short-circuit impedance (%)
S11-M-30301006,6.3,10,10.5,11/0.46002.34.0
S11-M-50501306,6.3,10,10.5,11/0.48702.04.0
S11-M-63631506,6.3,10,10.5,11/0.410401.94.0
S11-M-80801806,6.3,10,10.5,11/0.412501.94.0
S11-M-1001002006,6.3,10,10.5,11/0.415001.84.0
S11-M-1251252406,6.3,10,10.5,11/0.418001.74.0
S11-M-1601602806,6.3,10,10.5,11/0.422001.64.0
S11-M-2002003406,6.3,10,10.5,11/0.426001.54.0
S11-M-2502504006,6.3,10,10.5,11/0.430501.44.0
S11-M-3153154806,6.3,10,10.5,11/0.436501.44.0
S11-M-4004005706,6.3,10,10.5,11/0.443001.34.0
S11-M-5005006806,6.3,10,10.5,11/0.451001.24.0
S11-M-6306308106,6.3,10,10.5,11/0.462001.14.5
S11-M-8008009806,6.3,10,10.5,11/0.475001.04.5
S11-M-1000100011506,6.3,10,10.5,11/0.4103001.04.5
S11-M-1250125013606,6.3,10,10.5,11/0.4128000.94.5
S11-M-1600160016406,6.3,10,10.5,11/0.4145000.84.5
S11-M-2000200022806,6.3,10,10.5,11/0.4178200.65.0
S11-M-2500250027006,6.3,10,10.5,11/0.4207000.65.0
S11-M-30-309020,22/0.46602.15.5
S11-M-50-5013020,22/0.496025.5
S11-M-63-6315020,22/0.411451.95.5
S11-M-80-8018020,22/0.413701.85.5
S11-M-100-10020020,22/0.416501.65.5
S11-M-125-12524020,22/0.419801.55.5
S11-M-160-16029020,22/0.424201.45.5
S11-M-200-20033020,22/0.428601.35.5
S11-M-250-25040020,22/0.433501.25.5
S11-M-315-31548020,22/0.440101.15.5
S11-M-400-40057020,22/0.4473015.5
S11-M-50050068020,22/0.4566015.5
S11-M-63063081020,22/0.468200.96
S11-M-80080098020,22/0.482501.86
S11-M-10001000115020,22/0.4113300.76
S11-M-12501250135020,22/0.4132000.76
S11-M-16001600163020,22/0.4159500.66