Step down Dry type transformers are an important component of any business’s electrical system. They are used to reduce the voltage of an incoming electrical supply to a lower level, allowing for the safe and efficient use of electrical equipment. By using a step down Dry type transformer, businesses can improve their efficiency by reducing the amount of energy wasted due to voltage fluctuations.
The primary benefit of using a step down Dry type transformer is that it can help to reduce the amount of energy wasted due to voltage fluctuations. When the voltage of an incoming electrical supply is too high, it can cause electrical equipment to overheat and malfunction. By using a step down Dry type transformer, businesses can reduce the voltage of the incoming electrical supply to a level that is safe for their equipment. This helps to reduce the amount of energy wasted due to voltage fluctuations, improving the efficiency of the business’s electrical system.
Type
Rated capacity (KVA)
Voltage combination(KV)
No-load losses(W)
Load losses(W)
No-load current (%)
Short-circuit impedance (%)
SCH15-30
30
6,6.3,6.6,10,11/0.4
70
710
1.6
4.0
SCH15-50
50
6,6.3,6.6,10,11/0.4
90
1000
1.4
4.0
SCH15-80
80
6,6.3,6.6,10,11/0.4
120
1380
1.3
4.0
SCH15-100
100
6,6.3,6.6,10,11/0.4
130
1570
1.2
4.0
SCH15-125
125
6,6.3,6.6,10,11/0.4
150
1850
1.1
4.0
SC(B)H15-160
160
6,6.3,6.6,10,11/0.4
170
2130
1.1
4.0
SC(B)H15-200
200
6,6.3,6.6,10,11/0.4
200
2530
1.0
4.0
SC(B)H15-250
250
6,6.3,6.6,10,11/0.4
230
2760
1.0
4.0
SC(B)H15-315
315
6,6.3,6.6,10,11/0.4
280
3470
0.9
4.0
SC(B)H15-400
400
6,6.3,6.6,10,11/0.4
310
3990
0.8
4.0
SC(B)H15-500
500
6,6.3,6.6,10,11/0.4
360
4880
0.8
4.0
SC(B)H15-630
630
6,6.3,6.6,10,11/0.4
420
5880
0.7
4.0
SC(B)H15-630
630
6,6.3,6.6,10,11/0.4
410
5960
0.7
6.0
SC(B)H15-800
800
6,6.3,6.6,10,11/0.4
480
6960
0.7
6.0
SC(B)H15-1000
1000
6,6.3,6.6,10,11/0.4
550
8130
0.6
6.0
SC(B)H15-1250
1250
6,6.3,6.6,10,11/0.4
650
9690
0.6
6.0
SC(B)H15-1600
1600
6,6.3,6.6,10,11/0.4
780
11730
0.6
6.0
SC(B)H15-2000
2000
6,6.3,6.6,10,11/0.4
1000
14450
0.5
6.0
SC(B)H15-2500
2500
6,6.3,6.6,10,11/0.4
1200
17170
0.5
6.0
Another benefit of using a step down Dry type transformer is that it can help to reduce the risk of electrical fires. When the voltage of an incoming electrical supply is too high, it can cause electrical equipment to overheat and malfunction, leading to an increased risk of electrical fires. By using a step down Dry type transformer, businesses can reduce the voltage of the incoming electrical supply to a level that is safe for their equipment, reducing the risk of electrical fires.
Finally, using a step down Dry type transformer can help to reduce the cost of energy bills. By reducing the voltage of the incoming electrical supply, businesses can reduce the amount of energy they use, leading to lower energy bills. This can help businesses to save money on their energy costs, improving their overall efficiency.
In conclusion, step down Dry type transformers can help businesses to improve their efficiency by reducing the amount of energy wasted due to voltage fluctuations, reducing the risk of electrical fires, and reducing the cost of energy bills. By using a step down Dry type transformer, businesses can ensure that their electrical system is running safely and efficiently.