如何為您的應用選擇合適的中壓電力變壓器:低噪音製造商指南


為您的應用選擇中壓電源變壓器時,重要的是要考慮變壓器產生的雜訊程度。低噪音製造商必須考慮變壓器的尺寸、類型和設計,以確保其符合其噪音要求。本指南將概述為低噪音應用選擇中壓電源變壓器時要考慮的因素。

類型額定容量 KVA 電壓組合 KV 空載損耗 W 負載損耗 W 空載電流(%)短路阻抗(%)
S11-63063033,35/6.3,6.6,10.5,1183078701.106.5
S11-80080033,35/6.3,6.6,10.5,1198094101.006.5
S11-1000100033,35/6.3,6.6,10.5,111150115401.006.5
S11-1250125033,35/6.3,6.6,10.5,111410139400.906.5
S11-1600160033,35/6.3,6.6,10.5,111700166700.806.5
S11-2000200033,35/6.3,6.6,10.5,112180183800.706.5
S11-2500250033,35/6.3,6.6,10.5,112560196700.606.5
S11-3150315033,35/6.3,6.6,10.5,113040230900.567.0
S11-4000400033,35/6.3,6.6,10.5,113620273600.567.0
S11-5000500033,35/6.3,6.6,10.5,114320313800.487.0
S11-6300630033,35/6.3,6.6,10.5,115250350600.487.5
S11-8000800033,35/6.3,6.6,10.5,117200385000.427.5
S11-100001000033,35/6.3,6.6,10.5,118700453000.427.5
S11-125001250033,35/6.3,6.6,10.5,1110080539000.408.0
S11-160001600033,35/6.3,6.6,10.5,1112160658000.408.0
S11-200002000033,35/6.3,6.6,10.5,1114400795000.408.0
S11-250002500033,35/6.3,6.6,10.5,1117020941000.328.0
S11-315003150033,35/6.3,6.6,10.5,11202201129000.328.0
尺寸:變壓器的尺寸是選擇中壓電力變壓器時要考慮的重要因素。變壓器的尺寸將決定它可以處理的功率以及產生的噪音量。較大的變壓器通常比較小的變壓器更強大並且產生更多的噪音。
類型:變壓器的類型也是需要考慮的重要因素。不同類型的變壓器有不同的噪音等級。例如,乾式變壓器通常比油浸式變壓器更安靜。
設計:變壓器的設計也很重要。不同的設計會影響變壓器的噪音水平。例如,匝數較多的變壓器比較匝數較少的變壓器會產生較多的雜訊。

降噪:低噪音廠商也應考慮變壓器的降噪特性。許多變壓器都具有降噪功能,例如隔音、減振和降噪技術。這些功能有助於降低變壓器的噪音水平。

alt-288

安裝:變壓器的安裝也很重要。正確的安裝有助於降低變壓器的噪音水平。確保變壓器安裝在遠離交通、機械和其他噪音源等噪音源的位置非常重要。
透過考慮這些因素,低噪音製造商可以為其選擇合適的中壓電力變壓器。應用。透過選擇滿足噪音要求的變壓器,他們可以確保應用程式平穩且有效率地運作。