SC(B)11Rated capacity (KVA)Voltage combination(KV)No-load losses(W)Load losses(W)No-load current (%)Short-circuit impedance (%)
SC11-30306,6.3,6.6,10,11/0.41807102.44.0
SC11-50506,6.3,6.6,10,11/0.425010002.44.0
SC11-80806,6.3,6.6,10,11/0.434013801.84.0
SC11-1001006,6.3,6.6,10,11/0.436015701.84.0
SC11-1251256,6.3,6.6,10,11/0.442018501.64.0
SCB11-1601606,6.3,6.6,10,11/0.449021301.64.0
SCB11-2002006,6.3,6.6,10,11/0.456025301.44.0
SCB11-2502506,6.3,6.6,10,11/0.465027601.44.0
SCB11-3153156,6.3,6.6,10,11/0.479034701.24.0
SCB11-4004006,6.3,6.6,10,11/0.488039901.24.0
SCB11-5005006,6.3,6.6,10,11/0.4105048801.24.0
SCB11-6306306,6.3,6.6,10,11/0.4121058801.04.0
SCB11-6306306,6.3,6.6,10,11/0.4117059601.06.0
SCB11-8008006,6.3,6.6,10,11/0.4137069601.06.0
SCB11-100010006,6.3,6.6,10,11/0.4159081301.06.0
SCB11-125012506,6.3,6.6,10,11/0.4188096901.06.0
SCB11-160016006,6.3,6.6,10,11/0.42210117301.06.0
SCB11-200020006,6.3,6.6,10,11/0.42720144500.86.0
SCB11-250025006,6.3,6.6,10,11/0.43200171700.86.0
Person 1: Well, the main benefit is that they are more efficient than traditional oil-cooled transformers. They also require less maintenance and are more reliable. Plus, they are safer to use since there is no risk of oil spills or fires.
TypeRated capacity (KVA)Voltage combination(KV)No-load losses(W)Load losses(W)No-load current (%)Short-circuit impedance (%)
SZ11-2000200033,35/6.3,6.6,10.5,112300192400.806.5
SZ11-2500250033,35/6.3,6.6,10.5,112720206400.806.5
SZ11-3150315033,35/6.3,6.6,10.5,113230247100.727.0
SZ11-4000400033,35/6.3,6.6,10.5,113870291600.727.0
SZ11-5000500033,35/6.3,6.6,10.5,114640342000.687.0
SZ11-6300630033,35/6.3,6.6,10.5,115630368000.687.5
SZ11-8000800033,35/6.3,6.6,10.5,117870406000.607.5
SZ11-100001000033,35/6.3,6.6,10.5,119280481000.607.5
SZ11-125001250033,35/6.3,6.6,10.5,1110940569000.568.0
SZ11-160001600033,35/6.3,6.6,10.5,1113170703000.548.0
SZ11-200002000033,35/6.3,6.6,10.5,1115570828000.548.0