The use of Liquid immersed transformers in volume production manufacturing companies offers a number of advantages over traditional dry-type transformers. Liquid immersed transformers are more efficient, have a longer life span, and are more reliable than dry-type transformers. These benefits make them an attractive option for companies that require a high volume of production.
Type
Rated capacity (KVA)
Voltage combination(KV)
No-load losses(W)
Load losses(W)
No-load Current (%)
Short-circuit impedance (%)
SH15-M-30
30
6,6.3,10,10.5,11/0.4
33
630
1.50
4.0
SH15-M-50
50
6,6.3,10,10.5,11/0.4
43
910
1.20
4.0
SH15-M-63
63
6,6.3,10,10.5,11/0.4
50
1090
1.10
4.0
SH15-M-80
80
6,6.3,10,10.5,11/0.4
60
1310
1.00
4.0
SH15-M-100
100
6,6.3,10,10.5,11/0.4
75
1580
0.90
4.0
SH15-M-125
125
6,6.3,10,10.5,11/0.4
85
1890
0.80
4.0
SH15-M-160
160
6,6.3,10,10.5,11/0.4
100
2310
0.60
4.0
SH15-M-200
200
6,6.3,10,10.5,11/0.4
120
2730
0.60
4.0
SH15-M-250
250
6,6.3,10,10.5,11/0.4
140
3200
0.60
4.0
SH15-M-315
315
6,6.3,10,10.5,11/0.4
170
3830
0.50
4.0
SH15-M-400
400
6,6.3,10,10.5,11/0.4
200
4520
0.50
4.0
SH15-M-500
500
6,6.3,10,10.5,11/0.4
240
5140
0.50
4.0
SH15-M-630
630
6,6.3,10,10.5,11/0.4
320
6200
0.30
4.5
SH15-M-800
800
6,6.3,10,10.5,11/0.4
380
7500
0.30
4.5
SH15-M-1000
1000
6,6.3,10,10.5,11/0.4
450
10300
0.30
4.5
SH15-M-1250
1250
6,6.3,10,10.5,11/0.4
530
12000
0.20
4.5
SH15-M-1600
1600
6,6.3,10,10.5,11/0.4
630
14500
0.20
4.5
SH15-M-2000
2000
6,6.3,10,10.5,11/0.4
750
18300
0.20
5.0
SH15-M-2500
2500
6,6.3,10,10.5,11/0.4
900
21200
0.20
5.0
Liquid immersed transformers are more efficient than dry-type transformers. This is because the liquid coolant used in Liquid immersed transformers helps to dissipate heat more quickly and efficiently than air cooling. This allows the transformer to operate at higher temperatures and higher power levels, resulting in greater efficiency. Additionally, Liquid immersed transformers are able to operate at higher voltages than dry-type transformers, which can result in increased efficiency.
Liquid immersed transformers also have a longer life span than dry-type transformers. This is because the liquid coolant helps to protect the transformer from the damaging effects of heat and vibration. Additionally, the liquid coolant helps to reduce the amount of wear and tear on the transformer, resulting in a longer life span.
Finally, Liquid immersed transformers are more reliable than dry-type transformers. This is because the liquid coolant helps to reduce the risk of electrical shorts and other problems that can occur with dry-type transformers. Additionally, the liquid coolant helps to reduce the risk of fire and other safety hazards.
Overall, Liquid immersed transformers offer a number of advantages over dry-type transformers for volume production manufacturing companies. They are more efficient, have a longer life span, and are more reliable than dry-type transformers. These benefits make them an attractive option for companies that require a high volume of production.