How to Choose the Right Oil type transformer for Low Noise Applications: A Guide for Manufacturers

Choosing the right Oil type transformer for low noise applications can be a tricky process. As a manufacturer, you want to make sure you select the best transformer for your needs. Here are some tips to help you make the right choice. 1. Consider the size of the transformer. The size of the transformer will determine the amount of noise it produces. Smaller transformers tend to be quieter than larger ones. 2. Look at the transformer’s insulation. The insulation of the transformer will help reduce noise. Look for a transformer with high-quality insulation that is designed to reduce noise.
TypeRated capacity (KVA)Voltage combination(KV)No-load losses(W)Load losses(W)No-load Current (%)Short-circuit impedance (%)
SH15-M-30306,6.3,10,10.5,11/0.4336301.504.0
SH15-M-50506,6.3,10,10.5,11/0.4439101.204.0
SH15-M-63636,6.3,10,10.5,11/0.45010901.104.0
SH15-M-80806,6.3,10,10.5,11/0.46013101.004.0
SH15-M-1001006,6.3,10,10.5,11/0.47515800.904.0
SH15-M-1251256,6.3,10,10.5,11/0.48518900.804.0
SH15-M-1601606,6.3,10,10.5,11/0.410023100.604.0
SH15-M-2002006,6.3,10,10.5,11/0.412027300.604.0
SH15-M-2502506,6.3,10,10.5,11/0.414032000.604.0
SH15-M-3153156,6.3,10,10.5,11/0.417038300.504.0
SH15-M-4004006,6.3,10,10.5,11/0.420045200.504.0
SH15-M-5005006,6.3,10,10.5,11/0.424051400.504.0
SH15-M-6306306,6.3,10,10.5,11/0.432062000.304.5
SH15-M-8008006,6.3,10,10.5,11/0.438075000.304.5
SH15-M-100010006,6.3,10,10.5,11/0.4450103000.304.5
SH15-M-125012506,6.3,10,10.5,11/0.4530120000.204.5
SH15-M-160016006,6.3,10,10.5,11/0.4630145000.204.5
SH15-M-200020006,6.3,10,10.5,11/0.4750183000.205.0
SH15-M-250025006,6.3,10,10.5,11/0.4900212000.205.0
3. Consider the transformer’s cooling system. The cooling system of the transformer will help reduce noise. Look for a transformer with a cooling system that is designed to reduce noise.
4. Look at the transformer’s design. The design of the transformer will also affect the amount of noise it produces. Look for a transformer with a design that is designed to reduce noise. 5. Consider the transformer’s power rating. The power rating of the transformer will determine the amount of noise it produces. Look for a transformer with a power rating that is designed to reduce noise. By following these tips, you can make sure you select the right Oil type transformer for your low noise applications. With the right transformer, you can ensure that your products are as quiet as possible. alt-8112