How to Choose the Right Medium Voltage Power transformer for Your Application: A Guide for Low Noise Manufacturers
When selecting a medium voltage Power transformer for your application, it is important to consider the noise levels that the transformer will generate. Low noise manufacturers must take into account the transformer’s size, type, and design to ensure that it meets their noise requirements. This guide will provide an overview of the factors to consider when selecting a medium voltage Power transformer for low noise applications.
Type
Rated capacity (KVA)
Voltage combination(KV)
No-load losses(W)
Load losses(W)
No-load current (%)
Short-circuit impedance (%)
S11-630
630
33,35/6.3,6.6,10.5,11
830
7870
1.10
6.5
S11-800
800
33,35/6.3,6.6,10.5,11
980
9410
1.00
6.5
S11-1000
1000
33,35/6.3,6.6,10.5,11
1150
11540
1.00
6.5
S11-1250
1250
33,35/6.3,6.6,10.5,11
1410
13940
0.90
6.5
S11-1600
1600
33,35/6.3,6.6,10.5,11
1700
16670
0.80
6.5
S11-2000
2000
33,35/6.3,6.6,10.5,11
2180
18380
0.70
6.5
S11-2500
2500
33,35/6.3,6.6,10.5,11
2560
19670
0.60
6.5
S11-3150
3150
33,35/6.3,6.6,10.5,11
3040
23090
0.56
7.0
S11-4000
4000
33,35/6.3,6.6,10.5,11
3620
27360
0.56
7.0
S11-5000
5000
33,35/6.3,6.6,10.5,11
4320
31380
0.48
7.0
S11-6300
6300
33,35/6.3,6.6,10.5,11
5250
35060
0.48
7.5
S11-8000
8000
33,35/6.3,6.6,10.5,11
7200
38500
0.42
7.5
S11-10000
10000
33,35/6.3,6.6,10.5,11
8700
45300
0.42
7.5
S11-12500
12500
33,35/6.3,6.6,10.5,11
10080
53900
0.40
8.0
S11-16000
16000
33,35/6.3,6.6,10.5,11
12160
65800
0.40
8.0
S11-20000
20000
33,35/6.3,6.6,10.5,11
14400
79500
0.40
8.0
S11-25000
25000
33,35/6.3,6.6,10.5,11
17020
94100
0.32
8.0
S11-31500
31500
33,35/6.3,6.6,10.5,11
20220
112900
0.32
8.0
Size: The size of the transformer is an important factor to consider when selecting a medium voltage Power transformer. The size of the transformer will determine the amount of power it can handle and the amount of noise it will generate. Larger transformers are typically more powerful and generate more noise than smaller transformers.
Type: The type of transformer is also an important factor to consider. Different types of transformers have different noise levels. For example, dry-type transformers are typically quieter than oil-filled transformers.
Design: The design of the transformer is also important. Different designs can affect the noise levels of the transformer. For example, transformers with a higher number of turns will generate more noise than those with fewer turns.
Noise Reduction: Low noise manufacturers should also consider the noise reduction features of the transformer. Many transformers come with noise reduction features such as soundproofing, vibration dampening, and noise-canceling technology. These features can help reduce the noise levels of the transformer.
Installation: The installation of the transformer is also important. Proper installation can help reduce the noise levels of the transformer. It is important to ensure that the transformer is installed in a location that is away from noise sources such as traffic, machinery, and other sources of noise.
By considering these factors, low noise manufacturers can select the right medium voltage Power transformer for their application. By selecting a transformer that meets their noise requirements, they can ensure that their application runs smoothly and efficiently.