Exploring the Benefits of Vacuum Cast Coil (VCC) Dry type transformers from China Manufacturers: A Cost-Effective Solution for Your Power Needs

Are you looking for a cost-effective solution to your power needs? Vacuum Cast Coil (VCC) Dry type transformers from China manufacturers may be the answer. VCC Dry type transformers offer a number of advantages over traditional transformers, including improved efficiency, reduced noise, and increased safety. VCC Dry type transformers are made using a vacuum casting process, which eliminates the need for oil-filled transformers. This eliminates the risk of oil leakage, which can be a major safety hazard. Additionally, the vacuum casting process also reduces the amount of noise generated by the transformer, making it ideal for use in residential and commercial settings.
alt-663 The vacuum casting process also increases the efficiency of the transformer, allowing it to produce more power with less energy. This can result in significant cost savings over time, as the transformer will require less energy to operate. Additionally, the increased efficiency of the transformer also reduces the amount of heat generated, making it safer to use in areas where temperatures can reach extreme levels. Finally, VCC Dry type transformers are also more reliable than traditional transformers. The vacuum casting process ensures that the transformer is built to last, and it is less likely to suffer from breakdowns or other issues. This can help to reduce the amount of downtime associated with power outages, and it can also help to reduce the cost of repairs and maintenance. Overall, VCC Dry type transformers from China manufacturers offer a cost-effective solution to your power needs. With improved efficiency, reduced noise, increased safety, and increased reliability, these transformers can help to save you money in the long run. If you’re looking for a reliable and cost-effective solution to your power needs, consider investing in VCC Dry type transformers from China manufacturers.
SC(B)10 Rated capacity (KVA)Voltage combination(KV)No-load losses(W)Load losses(W)No-load current (%)Short-circuit impedance (%)
SC10-30306,6.3,6.6,10,11/0.41907102.44.0
SC10-50506,6.3,6.6,10,11/0.427010002.44.0
SC10-80806,6.3,6.6,10,11/0.437013801.84.0
SC10-1001006,6.3,6.6,10,11/0.440015701.84.0
SC10-1251256,6.3,6.6,10,11/0.447018501.64.0
SCB10-1601606,6.3,6.6,10,11/0.455021301.64.0
SCB10-2002006,6.3,6.6,10,11/0.463025301.44.0
SCB10-2502506,6.3,6.6,10,11/0.472027601.44.0
SCB10-3153156,6.3,6.6,10,11/0.488034701.24.0
SCB10-4004006,6.3,6.6,10,11/0.498039901.24.0
SCB10-5005006,6.3,6.6,10,11/0.4116048801.24.0
SCB10-6306306,6.3,6.6,10,11/0.4135058801.04.0
SCB10-6306306,6.3,6.6,10,11/0.4130059601.06.0
SCB10-8008006,6.3,6.6,10,11/0.4152069601.06.0
SCB10-100010006,6.3,6.6,10,11/0.4177081301.06.0
SCB10-125012506,6.3,6.6,10,11/0.4209096901.06.0
SCB10-160016006,6.3,6.6,10,11/0.42450117301.06.0
SCB10-200020006,6.3,6.6,10,11/0.43050144500.86.0
SCB10-250025006,6.3,6.6,10,11/0.43600171700.86.0