Understanding the Benefits of Step Up Dry type transformers with Class F Insulation from a Chinese Manufacturer
Step up Dry type transformers with Class F insulation from a Chinese manufacturer offer a number of benefits. These transformers are designed to provide reliable and efficient power conversion, and they are constructed with high-quality materials to ensure long-term performance.
The Class F insulation system used in these transformers is designed to provide superior protection against electrical faults and overloads. This insulation system is also designed to reduce the risk of fire and other hazards associated with electrical systems. Additionally, the insulation system is designed to reduce the amount of energy lost during the power conversion process, resulting in improved efficiency.
The dry type construction of these transformers also offers a number of benefits. This construction eliminates the need for oil-filled transformers, which can be hazardous and require regular maintenance. Additionally, the dry type construction reduces the risk of fire and other hazards associated with oil-filled transformers.
SC(B)11
Rated capacity (KVA)
Voltage combination(KV)
No-load losses(W)
Load losses(W)
No-load current (%)
Short-circuit impedance (%)
SC11-30
30
6,6.3,6.6,10,11/0.4
180
710
2.4
4.0
SC11-50
50
6,6.3,6.6,10,11/0.4
250
1000
2.4
4.0
SC11-80
80
6,6.3,6.6,10,11/0.4
340
1380
1.8
4.0
SC11-100
100
6,6.3,6.6,10,11/0.4
360
1570
1.8
4.0
SC11-125
125
6,6.3,6.6,10,11/0.4
420
1850
1.6
4.0
SCB11-160
160
6,6.3,6.6,10,11/0.4
490
2130
1.6
4.0
SCB11-200
200
6,6.3,6.6,10,11/0.4
560
2530
1.4
4.0
SCB11-250
250
6,6.3,6.6,10,11/0.4
650
2760
1.4
4.0
SCB11-315
315
6,6.3,6.6,10,11/0.4
790
3470
1.2
4.0
SCB11-400
400
6,6.3,6.6,10,11/0.4
880
3990
1.2
4.0
SCB11-500
500
6,6.3,6.6,10,11/0.4
1050
4880
1.2
4.0
SCB11-630
630
6,6.3,6.6,10,11/0.4
1210
5880
1.0
4.0
SCB11-630
630
6,6.3,6.6,10,11/0.4
1170
5960
1.0
6.0
SCB11-800
800
6,6.3,6.6,10,11/0.4
1370
6960
1.0
6.0
SCB11-1000
1000
6,6.3,6.6,10,11/0.4
1590
8130
1.0
6.0
SCB11-1250
1250
6,6.3,6.6,10,11/0.4
1880
9690
1.0
6.0
SCB11-1600
1600
6,6.3,6.6,10,11/0.4
2210
11730
1.0
6.0
SCB11-2000
2000
6,6.3,6.6,10,11/0.4
2720
14450
0.8
6.0
SCB11-2500
2500
6,6.3,6.6,10,11/0.4
3200
17170
0.8
6.0
Finally, these transformers are designed to be highly reliable and durable. The high-quality materials used in their construction ensure that they will last for many years with minimal maintenance. Additionally, the design of these transformers is designed to reduce the risk of electrical faults and overloads, resulting in improved safety.
Overall, step up Dry type transformers with Class F insulation from a Chinese manufacturer offer a number of benefits. These transformers are designed to provide reliable and efficient power conversion, and they are constructed with high-quality materials to ensure long-term performance. Additionally, the dry type construction eliminates the need for oil-filled transformers, and the insulation system is designed to reduce the risk of fire and other hazards associated with electrical systems. Finally, these transformers are designed to be highly reliable and durable, resulting in improved safety.