Oil type transformers are designed to operate at high altitudes by taking into account the effects of reduced air pressure and reduced cooling capacity. This is achieved by increasing the size of the transformer’s core and windings, as well as by using a higher grade of insulation. Additionally, the oil used in the transformer must be able to withstand the lower air pressure and higher temperatures that occur at higher altitudes.
Compared to Dry type transformers, Oil type transformers are better suited for high altitude operation due to their increased cooling capacity. The oil used in Oil type transformers is able to absorb more heat than air, allowing the transformer to operate at higher temperatures without overheating. Additionally, the oil is able to circulate more efficiently, allowing for better cooling of the transformer’s components.
Type
Rated capacity (KVA)
No-load losses(W)
Voltage combination (KV)
Load losses(W)
No-load current (%)
Short-circuit impedance (%)
S11-M-30
30
100
6,6.3,10,10.5,11/0.4
600
2.3
4.0
S11-M-50
50
130
6,6.3,10,10.5,11/0.4
870
2.0
4.0
S11-M-63
63
150
6,6.3,10,10.5,11/0.4
1040
1.9
4.0
S11-M-80
80
180
6,6.3,10,10.5,11/0.4
1250
1.9
4.0
S11-M-100
100
200
6,6.3,10,10.5,11/0.4
1500
1.8
4.0
S11-M-125
125
240
6,6.3,10,10.5,11/0.4
1800
1.7
4.0
S11-M-160
160
280
6,6.3,10,10.5,11/0.4
2200
1.6
4.0
S11-M-200
200
340
6,6.3,10,10.5,11/0.4
2600
1.5
4.0
S11-M-250
250
400
6,6.3,10,10.5,11/0.4
3050
1.4
4.0
S11-M-315
315
480
6,6.3,10,10.5,11/0.4
3650
1.4
4.0
S11-M-400
400
570
6,6.3,10,10.5,11/0.4
4300
1.3
4.0
S11-M-500
500
680
6,6.3,10,10.5,11/0.4
5100
1.2
4.0
S11-M-630
630
810
6,6.3,10,10.5,11/0.4
6200
1.1
4.5
S11-M-800
800
980
6,6.3,10,10.5,11/0.4
7500
1.0
4.5
S11-M-1000
1000
1150
6,6.3,10,10.5,11/0.4
10300
1.0
4.5
S11-M-1250
1250
1360
6,6.3,10,10.5,11/0.4
12800
0.9
4.5
S11-M-1600
1600
1640
6,6.3,10,10.5,11/0.4
14500
0.8
4.5
S11-M-2000
2000
2280
6,6.3,10,10.5,11/0.4
17820
0.6
5.0
S11-M-2500
2500
2700
6,6.3,10,10.5,11/0.4
20700
0.6
5.0
S11-M-30-
30
90
20,22/0.4
660
2.1
5.5
S11-M-50-
50
130
20,22/0.4
960
2
5.5
S11-M-63-
63
150
20,22/0.4
1145
1.9
5.5
S11-M-80-
80
180
20,22/0.4
1370
1.8
5.5
S11-M-100-
100
200
20,22/0.4
1650
1.6
5.5
S11-M-125-
125
240
20,22/0.4
1980
1.5
5.5
S11-M-160-
160
290
20,22/0.4
2420
1.4
5.5
S11-M-200-
200
330
20,22/0.4
2860
1.3
5.5
S11-M-250-
250
400
20,22/0.4
3350
1.2
5.5
S11-M-315-
315
480
20,22/0.4
4010
1.1
5.5
S11-M-400-
400
570
20,22/0.4
4730
1
5.5
S11-M-500
500
680
20,22/0.4
5660
1
5.5
S11-M-630
630
810
20,22/0.4
6820
0.9
6
S11-M-800
800
980
20,22/0.4
8250
1.8
6
S11-M-1000
1000
1150
20,22/0.4
11330
0.7
6
S11-M-1250
1250
1350
20,22/0.4
13200
0.7
6
S11-M-1600
1600
1630
20,22/0.4
15950
0.6
6
Oil type transformers are also designed to be more resistant to the effects of reduced air pressure. The transformer’s core and windings are designed to be larger and more robust, allowing them to withstand the increased stress caused by the lower air pressure. Additionally, the insulation used in the transformer must be able to withstand the higher temperatures and lower air pressure that occur at higher altitudes.
Overall, Oil type transformers are designed to operate at high altitudes by taking into account the effects of reduced air pressure and reduced cooling capacity. By increasing the size of the transformer’s core and windings, as well as by using a higher grade of insulation, Oil type transformers are able to withstand the higher temperatures and lower air pressure that occur at higher altitudes. Additionally, the oil used in the transformer is able to absorb more heat than air, allowing the transformer to operate at higher temperatures without overheating.