Step down Dry type transformers are an essential component of any business’s electrical system. They are used to reduce the voltage of an incoming electrical supply to a lower, safer level for use in the business’s operations. By doing so, they help to ensure the safety of employees and equipment, while also improving the efficiency of the business’s operations.
The use of step down Dry type transformers can help to improve the efficiency of a business in several ways. Firstly, they can help to reduce energy costs by ensuring that the business is only using the amount of electricity it needs. By reducing the voltage of the incoming supply, the business can use less electricity, resulting in lower energy bills.
Secondly, step down Dry type transformers can help to improve the safety of the business’s operations. By reducing the voltage of the incoming supply, the risk of electrical shock is greatly reduced. This can help to protect employees and equipment from potential harm.
Type
Rated capacity (KVA)
Voltage combination(KV)
No-load losses(W)
Load losses(W)
No-load current (%)
Short-circuit impedance (%)
SCH15-30
30
6,6.3,6.6,10,11/0.4
70
710
1.6
4.0
SCH15-50
50
6,6.3,6.6,10,11/0.4
90
1000
1.4
4.0
SCH15-80
80
6,6.3,6.6,10,11/0.4
120
1380
1.3
4.0
SCH15-100
100
6,6.3,6.6,10,11/0.4
130
1570
1.2
4.0
SCH15-125
125
6,6.3,6.6,10,11/0.4
150
1850
1.1
4.0
SC(B)H15-160
160
6,6.3,6.6,10,11/0.4
170
2130
1.1
4.0
SC(B)H15-200
200
6,6.3,6.6,10,11/0.4
200
2530
1.0
4.0
SC(B)H15-250
250
6,6.3,6.6,10,11/0.4
230
2760
1.0
4.0
SC(B)H15-315
315
6,6.3,6.6,10,11/0.4
280
3470
0.9
4.0
SC(B)H15-400
400
6,6.3,6.6,10,11/0.4
310
3990
0.8
4.0
SC(B)H15-500
500
6,6.3,6.6,10,11/0.4
360
4880
0.8
4.0
SC(B)H15-630
630
6,6.3,6.6,10,11/0.4
420
5880
0.7
4.0
SC(B)H15-630
630
6,6.3,6.6,10,11/0.4
410
5960
0.7
6.0
SC(B)H15-800
800
6,6.3,6.6,10,11/0.4
480
6960
0.7
6.0
SC(B)H15-1000
1000
6,6.3,6.6,10,11/0.4
550
8130
0.6
6.0
SC(B)H15-1250
1250
6,6.3,6.6,10,11/0.4
650
9690
0.6
6.0
SC(B)H15-1600
1600
6,6.3,6.6,10,11/0.4
780
11730
0.6
6.0
SC(B)H15-2000
2000
6,6.3,6.6,10,11/0.4
1000
14450
0.5
6.0
SC(B)H15-2500
2500
6,6.3,6.6,10,11/0.4
1200
17170
0.5
6.0
Finally, step down Dry type transformers can help to improve the reliability of the business’s operations. By reducing the voltage of the incoming supply, the risk of power surges and other electrical issues is greatly reduced. This can help to ensure that the business’s operations are running smoothly and efficiently.
In conclusion, step down Dry type transformers can help to improve the efficiency of a business in several ways. By reducing the voltage of the incoming supply, they can help to reduce energy costs, improve safety, and improve reliability. As such, they are an essential component of any business’s electrical system.
The Benefits of Working with an ISO9001 Certified Factory in China
فوائد اختيار الشركة المصنعة للمحولات المملوءة بالسوائل مع أوقات التسليم السريعة عندما يتعلق الأمر باختيار الشركة المصنعة للمحولات المملوءة بالسوائل، فإن…
Dry type Distribution transformers are an increasingly popular choice for businesses looking to upgrade their electrical systems. These transformers offer a…